TVP-2914
19
Point
X, Y LIMITS (mm)
BG, RG
BG
a
0,4
0,4
b, c
1,2
1,2
d, e
1,0
1,0
f, g, h, j
1,5
2,0
f’, g', h', j'
1,2
1,5
k, l, m, n
1,2
1,2
s, t, u, v
1,0
1,0
2.6
Video
2.6.1 Sensibility and Signal /Noise Rate
a)
Adjust the TV to a “PP” condition.
b)
Apply to the antenna input a 60dB
µ
V signal with 88% AM modulation, 1kHz
sine wave (Frequency and channel factory defined).
c)
Connect at the output video detector na AC voltmeter and read the voltage
V
AC.
d)
Turn off the AM modulation and read the noise level “Vr” (AC voltmeter)
.
e)
Calculate the signal-noise rate as following:
S/N=20 log (V
AC
/ V
R
).
f)
Reduce the output level signal generator till the rate S/N reach 20 dB. In
this condition the output level signal generator is the sensibility in dBuV.
Minimum
Nominal
Maximum
Unit
Sensibility
-
37,00
46,00
dB
µ
V
S/N
40,00
50,00
-
dB