Installation
10
Black/White LCD Mini-Touch Panels
Using the AXlink mini-XLR connector and external 12 VDC power supply (AXT-MLC
and AXW-MLC)
Connect the Central Controller’s AXlink connector to the mini-XLR connector and external 12
VDC power supply to the rear panel of the AXT-MLC or AXW-MLC, as shown in FIG. 10.
Using AXlink for data and power (AXM-MLC)
Connect the Central Controller’s AXlink connector to the AXlink connector on the touch panel for
data and 12 VDC power as shown in FIG. 11.
Using AXlink for data with a 12 VDC power supply
Connect the Central Controller’s AXlink connector to the AXlink connector on the touch panel and
external 12 VDC power supply, as shown in FIG. 12.
FIG. 10
Mini-XLR connector to external 12 VDC power supply and Central Controller wiring diagram
FIG. 11
AXlink wiring diagram
1
2
3
4
GND-
AXM
AXP
PWR+
Control system
1
2
3
4
GND-
AXM
AXP
PWR+
1
2
3
4
4-pin mini-XLR connector
PWR+
GND-
12 VDC power supply
PWR (+)
AXP
AXM
GND (-)
PWR (+)
AXP
AXM
GND (-)
AXlink connector on the touch panel
Central Controller
If you are using power from AXlink, disconnect the wiring from the Central Controller
before wiring the touch panel.
FIG. 12
AXlink and external 12 VDC power supply wiring diagram
PWR (+)
AXP
AXM
GND (-)
PWR (+)
AXP
AXM
GND (-)
AXlink connector on the touch panel
Central Controller
PWR (+)
GND (-)