background image

68-1909-01 

Rev. B

01 12

TLP 1000MV and TLP 1000TV

User Guide

TouchLink

TouchLink Touchpanels

Содержание TLP 1000MV

Страница 1: ...68 1909 01 Rev B 01 12 TLP 1000MV and TLP 1000TV User Guide TouchLink TouchLink Touchpanels ...

Страница 2: ...al verwenden sollten Sie alle Sicherheits und Bedienungsanleitungen genau durchlesen und verstehen Aufbewahren der Anleitungen Die Hinweise zur elektrischen Sicherheit des Produktes sollten Sie aufbewahren damit Sie im Bedarfsfall darauf zurückgreifen können Befolgen der Warnhinweise Befolgen Sie alle Warnhinweise und Anleitungen auf dem Gerät oder in der Benutzerdokumentation Keine Zusatzgeräte V...

Страница 3: ...ted in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense NOT...

Страница 4: ...xamples of computer or device responses mentioned in this guide the character 0 is used for the number zero and O represents the capital letter o Computer responses and directory paths that do not have variables are written in the font shown here Reply from 208 132 180 48 bytes 32 times 2ms TTL 32 C Program Files Extron Variables are written in slanted form as shown here ping xxx xxx xxx xxx t SOH...

Страница 5: ...Configurator and Global Configurator Installation 18 Using the TouchLink Panel Web Pages 19 Updating the Firmware 21 Updating Firmware Using Extron Firmware Loader 21 Updating Firmware Using GUI Configurator 22 Updating Firmware From a Web Browser 23 Using GUI Configurator 24 Using Global Configurator 29 Specifications 34 Accessories and Part Numbers 40 Included Parts 40 Optional Parts 40 Mounting...

Страница 6: ...TLP 1000MV and TLP 1000TV Contents vi ...

Страница 7: ...ated with those graphics providing versatility and adaptability to the configuration and control of an AV system A motion sensor light sensor and two speakers provide sleep mode auto dimming and audible feedback The TLP 1000MV is intended to be wall or rack mounted The TLP 1000TV comes with a stand that allows it to be placed on a desktop If the stand is removed the unit can be mounted on a wall o...

Страница 8: ... Detector RS 232 RS 232 Contact Closure IR Control to DVD IR Control from IPL 250 Relay Extron IR Emitter Relay Figure 1 TLP 1000MV Application Diagram Programmable LEDs provide feedback about various system states as defined by the user Light sensor adjusts LCD screen backlighting to compensate for ambient lighting Motion sensor When no motion is detected for a user defined period of time the uni...

Страница 9: ...lobal Configurator Other Hardware An Extron IP Link control processor must also be connected to the same network domain as the TouchLink panel Suggested models include IPL T S series for example IPL T S4 IPL 250 IPL T CR48 IPL T SFI244 IPCP 305 IPCP 505 See the Extron Website www extron com for further information about these products TLP 1000MV and TLP 1000TV Introduction 3 ...

Страница 10: ...nsor When no motion has been detected for a user defined period of time the unit enters sleep mode When motion is detected by the sensor the screen display is restored and active b Microphone is located below the LCD screen c Connection status LED is unlit during normal operation Blinks red if the connection to the IP Link controller is lost d Configurable LEDs 2 two LEDs on the top corners of the...

Страница 11: ...lay frame The sensor monitors the level of ambient light and adjusts the screen brightness and button backlighting The sensor can only be viewed from above the panel Reset Buttons and LED There are two buttons and an LED recessed behind the faceplate h ij Figure 4 TLP 1000MV Front Panel with the Bezel Removed h Menu button activates the on screen menus for calibrating the unit see page 14 i Reset ...

Страница 12: ...nect a twisted pair cable terminated with an RJ 45 connector to provide video and audio input from an Extron MTP transmitter CAUTION Connect the MTP transmitter to the MTP socket and the network connector to the network socket Although both use RJ 45 connectors the MTP socket on the left must be connected to an MTP transmitter and the network socket on the right must be connected to a LAN The wire...

Страница 13: ... Connecting the Power over Ethernet Power Supply CAUTIONS The TLP 1000MV and TLP 1000TV are intended for connection to a Power over Ethernet circuit for intrabuilding use only and are considered a Network Environment 0 per IEC TR62101 Always use a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may damage the supply...

Страница 14: ...mage to the supply and the end product Unless otherwise stated the AC DC adapters are not suitable for use in air handling spaces or in wall cavities The power supply is to be located within the same vicinity as the Extron AV processing equipment in an ordinary location Pollution Degree 2 secured to the equipment rack within the dedicated closet podium or desk The installation must always be in ac...

Страница 15: ...mation about the system The LEDs can be programmed to light red or green and have two rates blinking and always on e LCD screen has a 1024x600 resolution with a touch overlay A graphical user interface designed using the Extron GUI Configurator software see page 24 displays buttons text or icons on the screen page 24 These are configured for a range of user defined functions using the Extron Globa...

Страница 16: ... The following features and connections are available on the back panel h Menu button activates the on screen menus for calibrating the unit see page 14 i Reset button allows the unit to be reset in any of four different modes see Reset Modes on page 47 j Reset LED provides feedback about the reset status when the user presses the reset button see Reset Modes on page 47 k MTP signal adjustment con...

Страница 17: ...ron IP Link control processor must also be connected to the same network domain Suggested models are listed on page 3 Use a straight through Ethernet cable to connect the panel to a switch or router Use a crossover cable to connect the panel directly to a computer Extron recommends using a Power over Ethernet PoE power supply Use a straight through Ethernet cable to connect the power supply to a s...

Страница 18: ...he 12 VDC 1 0 A power supply should be used only for setup or troubleshooting If both power supplies are connected to the TLP 1000TV the PoE power supply takes precedence Power Receptacle DC Power Cord Captive Screw Connector AC Power Cord Ground 12 VDC External Power Supply 12 VDC 1 A SECTION A A Ridges Smooth Power Supply Output Cord A A 3 16 5 mm Max Figure 12 Power Supply Connection CAUTION Se...

Страница 19: ...in accordance with the VESA FDMI standard type D 75 mm see VESA mounting the TLP 1000TV on page 46 p Kensington Security Slot allows the touchpanel to be locked to a table or other flat surface The lock is not provided and must be purchased separately TLP 1000MV and TLP 1000TV Panel Features 13 ...

Страница 20: ...twork and Video that can be selected by pressing the appropriate button at the left side of the screen There is also an Exit button at the bottom left corner of the screen Pressing this button applies and saves any changes and leaves the menu screens Main Screen Main Volume Time Network Video Exit On On Down Up Sleep timer 300 Sec Down Up Backlight 073 Auto Backlight Wake on Motion PoE Active Figu...

Страница 21: ...n screen buttons to toggle the Auto Backlight or Wake on Motion options between Off and On Volume Screen Main Volume Time Network Video Exit Master 120 Click 120 Sounds 120 Down Up Down Up Down Up Down Up Line In 120 Figure 14 Volume Screen Press the Down or Up buttons to highlight one of the adjustable audio features Use the Down and Up buttons to adjust the following settings Master volume betwe...

Страница 22: ...set the IP address or subnet mask press the appropriate button When one of the buttons is selected an on screen keypad appears that allows the user to select Clear or digits between 0 and 9 and dot NOTE The factory default IP address for both the TLP 1000MV and TLP 1000TV is 192 168 254 254 The default subnet mask is 255 255 0 0 Consult with your IT department to ensure these addresses are correct...

Страница 23: ...een 0 and 255 default 128 Touch Calibration Screen After setting the Main Volume Time Network and Video values press the Menu button a second time to begin calibrating the touch area of the touchpanel Press and Hold Highlighted Box Until Color Changes Figure 18 Touch Calibration Screen Press on the green box until the color reverts to gray with a white border and a second box is highlighted Repeat...

Страница 24: ... from the TLP unit to Global Configurator where control functions are assigned to the text and graphic items in the layout After assigning the control functions the project is rebuilt and uploaded to the controller These two programs provide versatility and adaptability for configuration and control of an AV system as it grows and evolves Installing the Software GUI Configurator and Global Configu...

Страница 25: ...e to GUI Configurator or Global Configurator and click Download next to the program Follow the on screen instructions to complete installation A folder is created on the C drive and an icon may be placed on the desktop Using the TouchLink Panel Web Pages Both the TouchLink panels have default web pages that can be used to read and change the current settings of the panels The web pages can be acce...

Страница 26: ... on screen menus Figure 20 System Settings Page 3 Selecting Passwords allows the user to set passwords for an administrator and a user To set a password follow the instructions at the top of the page Figure 21 Passwords Page 4 To upgrade the firmware select Firmware Upgrade More detailed instructions are found in the Updating Firmware from a Web Browser section on page 23 TLP 1000MV and TLP 1000TV...

Страница 27: ...on Firmware Loader 1 Power on a computer that is connected to the same network as the touchpanel 2 Install the Extron Firmware Loader utility onto the computer if it is not already present This is on the software disc that ships with unit or can be downloaded free of charge from the Extron website www extron com To install from the disc insert the disc into the DVD ROM drive of the computer and fo...

Страница 28: ...re Loader screen opens with the TLP 1000MV or TLP 1000TV listed in the device pane 10 Click Begin The firmware transfer begins and takes approximately three minutes When the Total Progress bar shows Completed select Exit from the File menu to exit Firmware Loader Updating Firmware Using GUI Configurator 1 Set up the computer and touchpanel as described in steps 1 and 2 in the previous section Upda...

Страница 29: ...f the TLP 1000 unit into the address box The browser opens the TouchLink panel web pages see page 19 Figure 25 Firmware Upgrade Web Page 6 Click the Configuration tab at the top of the page and then select Firmware Upgrade from the bar on the left 7 Use the Browse button to navigate to and select the firmware file that was saved in step 4 8 Click Upload The Touchpanel screen shows the message Firm...

Страница 30: ...ram NOTE To configure the touchpanel use GUI Configurator version 1 2 or later To use the GUI Configurator program follow these instructions 1 Double click the desktop icon A splash screen appears momentarily and then the program opens at the main screen behind the GUI Configurator Start Options dialog box Figure 26 Opening GUI Configurator Figure 27 GUI Configurator Start Options Dialog Box TLP 1...

Страница 31: ...and allow you to select the size and type of Touchlink panel If you are creating a project from an existing template you can use the factory created templates or you can select a template that you have previously created Open an Existing Project Clicking OK opens a dialog box that allows you to navigate to an existing project for modification Figure 29 GUI Configurator Dialog Box to Open an Existi...

Страница 32: ...rom a Panel Clicking OK opens a dialog box that allows you to download a file that has been uploaded to a panel Figure 30 GUI Configurator Download Project Dialog Box In the dialog box that opens enter the IP address of the panel and use the Browse button to navigate to a folder where the file will be saved Check Open the project and Close Download Manager Click OK The project is downloaded to you...

Страница 33: ...lp file in the Help menu click Contents or press the F1 key while within the program Figure 31 GUI Configurator Main Screen 4 To save the project select Save Project from the File menu The project file is saved If this is the first time saving the project file the Save As dialog box appears If the Save As dialog box appears a Browse for the location where the project file is to be saved b Enter a ...

Страница 34: ...e address property in the right pane and type in the correct IP address Update any other properties as required e Repeat steps 5b 5d to add further panels if required 6 To upload a project to a TouchLink panel a From the Project menu select Upload to Selected Panels The Build Manager dialog box opens showing the build progress After the build is complete this dialog box closes and the File Upload ...

Страница 35: ...This section provides an overview of the Global Configurator program For complete information about the program consult the Global Configurator help file click Contents in the Help menu or press the F1 key while within the program This section describes how to set up Global Configurator project with an IPL 250 Setting up a project with another IP Link product is similar but you should consult the ...

Страница 36: ...trol processor b The default Telnet connection is port 23 and HTTP is port 80 so these values do not usually need to be changed c If necessary set administrator and user passwords d If required set the date and time e Checking the Set Device as GlobalViewer Host box is optional For more information about what a GlobalViewer host is see the Global Configurator help file TLP 1000MV and TLP 1000TV Co...

Страница 37: ...k control processor The default value is 192 168 254 254 but this may have been changed Check with your IT department to verify the address c Enter a display name into the text box This is what the device will be known as in the Global Configurator project d Checking the Make this device a GlobalViewer Host check box is optional e Set the Telnet port usually 23 and the web port usually 80 f If the...

Страница 38: ...he available ports Figure 37 Configuring an IP Link Device 6 Select TouchPanel Port 1 The screen shows the available options for the TouchLink panel To add the GUI Configurator project that was uploaded to the TouchLink panel click Click here to add one Figure 38 Adding a TouchLink Panel TLP 1000MV and TLP 1000TV Configuration Software 32 ...

Страница 39: ...the Telnet port usually 23 and if necessary enter the password c Check the Import Apply Layout box and click OK The window now shows the GUI from the TouchLink panel Figure 40 Touchpanel GUI Loaded Onto Global Configurator 3 8 Use Global Configurator to associate functions with the screen elements designed in GUI Configurator see the Global Configurator help file TLP 1000MV and TLP 1000TV Configur...

Страница 40: ...ject storage 16 MB for system use Control Ethernet interface Ethernet control communications port 1 RJ 45 female connector Ethernet data rate 10 100Base T half full duplex with autodetect Ethernet protocol ICMP IP TCP control UDP DHCP Telnet Default settings Link speed and duplex level autodetected IP address 192 168 254 254 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DHCP off Program control ...

Страница 41: ...al Power Supplied by an included power over Ethernet PoE adapter or by an optional external 12 VDC 1 A power supply Power supply External Input 100 240 VAC 50 60 Hz Output PoE 802 3af compliant 48 VDC 0 35 A 16 8 watts Power consumption Device 12 7 watts 48 VDC PoE Device and power supply 15 3 watts 100 240 VAC 50 60 Hz Power over Ethernet PoE input requirements Complies with PoE 802 3af class 3 T...

Страница 42: ...5 30 cm FRONT VIEW BOTTOM VIEW Product weight 2 7 lbs 1 2 kg Shipping weight 6 lbs 3 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI Environmental Complies with the applicable requirements of RoHS and WEEE MTBF 30 000 hours Warranty 3 years parts and labor touchscreen display and overlay component...

Страница 43: ... DHCP Telnet Default settings Link speed and duplex level autodetected IP address 192 168 254 254 Subnet mask 255 255 0 0 Default gateway 0 0 0 0 DHCP off Program control Extron Global Configurator v3 1 or higher GUI Configurator v1 2 or higher for Windows Extron Simple Instruction Set SIS Microsoft Internet Explorer ver 6 or higher Telnet Control touchpanel Motion sensor On off Light sensor On of...

Страница 44: ... Device 12 7 watts 48 VDC PoE Device and power supply 15 3 watts 100 240 VAC 50 60 Hz Power over Ethernet PoE input requirements Complies with PoE 802 3af class 3 Temperature humidity Storage 4 to 140 F 20 to 60 C 10 to 90 noncondensing Operating 32 to 122 F 0 to 50 C 10 to 90 noncondensing Cooling Convection vents on top rear Thermal dissipation Device 43 5 BTU hr Device and power supply 52 3 BTU...

Страница 45: ...IEW TLP 1000TV Product weight 5 2 lbs 2 4 kg Shipping weight 8 lbs 4 kg Vibration ISTA 1A in carton International Safe Transit Association Regulatory compliance Safety CE c UL UL EMI EMC CE C tick FCC Class A ICES VCCI Environmental Complies with the applicable requirements of RoHS and WEEE MTBF 30 000 hours Warranty 3 years parts and labor touchscreen display and overlay components are covered fo...

Страница 46: ...x for TLP 1000MV black 70 950 02 EWB 1000 external wall box for TLP 1000MV white 70 950 03 LPVM 1 VESA mounting kit for TLP 1000TV 60 1099 02 SMA 1 swivel mount adapter for TLP 1000TV 70 747 01 6 Spanner head screwdriver 100 710 01LF PS 1210 C 12 VDC 1 0 A desktop power supply with captive screw connector 70 775 01 IPL T S1 IP Link Control Processor 60 801 81 IPL T S2 IP Link Control Processor 60 ...

Страница 47: ... Tma 122 F 50 C specified by Extron Reduced air flow Install the equipment in the rack so that the equipment gets adequate air flow for safe operation Mechanical loading Mount the equipment in the rack so that uneven mechanical loading does not create a hazardous condition Circuit overloading Connect the equipment to the supply circuit and consider the effect that circuit overloading might have on...

Страница 48: ...ional Extron recommends using the Power over Ethernet power supply provided However you may use the LAN port only as a network connection and connect a 12 VDC 1 0 A power supply not provided to the 2 pole captive screw power input See the cautions on page 7 for very important information about power supplies 7 Push excess cables into the wall cavity 8 Ensure the five locking arms three at the top ...

Страница 49: ...h a network connection and power from a Power over Ethernet power supply Connect an S video or composite video source to the RJ 45 MTP input Optional Extron recommends using the Power over Ethernet power supply provided However you may use the LAN port only as a network connection and connect a 12 VDC 1 0 A power supply not provided to the 2 pole captive screw power input See the cautions on page ...

Страница 50: ...Extron SMA 1 swivel mount adapter This allows the unit to be mounted permanently yet swivel up to 180 in either direction 1 Remove the back cover and base cover using the Extron removal tool as described in Removing the TLP 1000TV Base for VESA Mounting on the next page 2 Set the TLP 1000TV on its back on a flat surface and remove the screw holding the locking plate at the bottom of the base This ...

Страница 51: ...ck cover by inserting the Extron removal tool provided into the notches on each side 2 Remove the base cover by inserting the Extron removal tool into the notches on the base Cable Runway Hinges 2 VESA Mounting Holes 4 Spanner Drive Security Screws 2 for each Hinge Figure 46 TLP 1000TV with the Base and Back Covers Removed TLP 1000MV and TLP 1000TV Mounting 45 ...

Страница 52: ...as described in the previous section 2 If necessary connect the cables and fasten them to the back of the touchpanel with zip ties 3 Attach the small back cover provided Fit the bottom catches into the slots on the bottom of the panel and snap the side catches into place 4 Once the base and back have been removed VESA mount the TLP 1000TV by securing plate 2 of the Extron LPVM 1 part number 60 109...

Страница 53: ...rt mapping back to factory default Turns DHCP off Turns events off This mode is useful for troubleshooting 5 Hold down the Reset button for about 9 seconds until the Reset LED blinks three times once at 3 seconds again at 6 seconds again at 9 seconds Then release and press Reset momentarily for 1 second within 1 second This mode performs a complete reset to factory defaults except the firmware Doe...

Страница 54: ...uilding 16 Ichibancho Chiyoda ku Tokyo 102 0082 Japan Europe Africa and the Middle East Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135 Joo Seng Road 04 01 PM Industrial Bldg Singapore 368363 Singapore Middle East Extron Middle East Dubai Airport Free Zone F12 PO Box 293666 United A...

Отзывы: