Tool Set Up
Various components of the OptiCam 2 Tool:
1. Select the proper Launch Cord and Cradle. For each connector type, select the correct launch cord and cradle for ter-
mination use.
Connector Type, Launch Cord, and Cradle cross reference table
Connector Type
Launch Cord
Cradle*
LC single mode
yellow cable, 1.25mm single mode(P/N: FOLPC-
1.25SM)
LC cradle, black (P/N: FLCC2)
LC multimode: OM1, OM2, OM3, and
OM4
orange cable, 1.25mm multimode(P/N: FOLPC-
1.25MM)
LC cradle, black (P/N: FLCC2)
SC single mode
yellow cable, 2.5mm single mode(P/N: FOLPC-
2.5SM)
SC cradle, gray (P/N: FSCC2)
SC multimode: OM1, OM2, OM3, and
OM4
orange cable, 2.5mm multimode(P/N: FOLPC-
2.5MM)
SC cradle, gray (P/N: FSCC2)
ST single mode
yellow cable, 2.5mm single mode(P/N: FOLPC-
2.5SM)
ST cradle, gray (P/N: FSTC2)
ST multimode: OM1, OM2, OM3, and
OM4
orange cable, 2.5mm multimode(P/N: FOLPC-
2.5MM)
ST cradle, gray (P/N: FSTC2)