OptiCam 2 FS133 Termination Tool User Manual
-
29
-
Note
: 1.25 millimeter cord is shown for reference. The process is the same for the 2.5 millimeter cord.
5. Twist the split sleeve and pull to remove it from the assembly, exposing the tip of the fiber.
6. Wet an area of the fiber optic cleaning system wipes with fiber optic cleaning solution.
7. Clean the ferrule end faces of any connector or launch cord end, using a dry lint-free wipe.