Copyright
©
2001 Panduit Corp.
PA24481A01
All Rights Reserved
11/2001
4
D. Reverse the gage and try to insert the NO-GO side into the crimping die (Do Not use excessive force). The
NO-GO side may partially enter the die closure but must not pass completely through.
E. If both the GO and NO-GO conditions are met; the tool is dimensionally correct – if either condition fails,
adjust the CRIMP DIE CLOSURE as follows:
1. Remove lock screw with small (2 mm)
Allen wrench [see Fig. 2].
2. With adjustment wrench provided, turn adjustment pin one notch – each notch produces approximately
.002” of adjustment. A clockwise turn increases the die closure and a counter-clockwise turn decreases
the die closure.
3. Close the tool and plug gage the die closure as instructed above. If the GO/NO-GO conditions are not
met, repeat Step (2) in one notch increments until the tool is gages to be dimensionally correct.
Replace and tighten lock screw after final adjustment.
F. If the above procedure fails to satisfy all GO and NO-GO conditions, contact your local
PANDUIT
Sales
Office.
PRODUCT INFORMATION CHART - TOOL NO. CT-460
Crimp
Die
PAN-TERM™ Terminal
Part Number
Wire Range
AWG
Wire Strip Length:
+ 1/32 / - 0 (in.)
PN 14-F, FF, LF, R
BSN 14*
18 - 14
7/32
PNF 14-F, LF, R
PTF 14-R
18 - 14
5/16
PN 14-SLF
16 - 14
7/32
PNF 14-SLF
PV 14-SLF
16 - 14
5/16
DV 14-250*
16 - 14
9/32
16 - 14
BLUE
JN 218-216*
22 - 16
7/16
PN 10-F, FF, LF, R
BSN 10*
14-10
9/32
PNF 10-F, LF, R
PTF 10-R
14-10
3/8
PN 10-SLF
12-10
9/32
PNF 10-SLF
12/10
3/8
PV 10-SLF
12-10
5/16
DV 10-250*
12-10
9/32
12-10
YELLOW
JN 418-212*
18-12
1/2
FIG. 7
* Denotes locator must be removed before terminal is crimped.