Copyright
©
2001 Panduit Corp.
PA24481A01
All Rights Reserved
11/2001
2
FIG. 5
INSULATED TERMINAL INSTRUCTIONS
1. With handles in open position, insert terminal in proper
size die so that tongue slides into locator slot. See
Figure 7 for selection of proper size die.
2. Position terminal against locator and close handles until
barrel is held snugly in place -- do not deform barrel.
3. Insert stripped wire into terminal until conductor extends
beyond barrel. See Figure 7 for wire strip length.
4. Crimp by closing handles until controlled cycle device
releases. Handles will open automatically and crimped
terminal may be removed.
INSULATED SPLICE INSTRUCTIONS
1. Remove locator using a 2.5mm Allen wrench on the
locator retention screw [see Fig. 1].
2. With locator removed and handles opened, insert splice
in proper size die so that barrel extends 1/16" beyond
insulation closures.
3. Close handles until barrel is held snugly in position -- do
not deform barrel.
4. Insert stripped wire into splice and crimp by closing
handles until controlled cycle device releases.
5. Remove splice and repeat operation for crimping other
half of barrel.
INSULATED WIRE JOINT INSTRUCTIONS
1. Remove locator using a 2.5mm Allen wrench on the
locator retention screw [see Fig. 1].
2. With terminal locator removed, insert wire joint in
proper size die so that ribs of molded insulator are
positioned against face of tool.
3. Twist ends of stripped wire together, trim and insert
into wire joint.
4. Crimp by closing handles until controlled cycle
device releases. Handles will open automatically
and crimped joint may be removed.
FIG. 3
FIG. 4