The Web GUI
Zone
When the AT-HDVS-200-TX is connected to the AT-HDVS-200-RX, the system is placed in
kit mode
. In this mode,
the drop-down list boxes will be disabled and the HDBaseT baud rate will be locked at 115200.
If the AT-HDVS-200-TX is connected to another HDBaseT device, such as the AT-UHD-CLSO-824, each of these
drop-down list boxes can be set to the baud rate of the HDBaseT RS-232 settings on the corresponding device.
TX RS-232
The RS-232 settings of the RS-232 port on the AT-HDVS-200-TX. Click the
Save
button to save the settings.
Setting
Description
Baud rate
Sets the baud rate. The following options are available: 2400, 9600, 19200, 38400,
56000, 57600, 115200.
Data bit
Sets the number of data bits used to represent each character of data. The following
options are available: 7 or 8.
Parity
Sets the parity bit, which can be included with each character to detect errors during
the transmission of data. The following options are available: None, Odd, or Even.
Stop bit
Sets the stop bit. Stop bits are sent at the end of each character, allowing the client
to detect the end of a character stream. The following options are available: 1 or 2.