AT-HDR-SW-51
29
Device Operation
The AT-HDR-SW-51 provides eight memory locations which can be used to store EDID data. Any downstream EDID
can be captured and stored in these locations. Each memory location is non-volatile and captured EDID data is
stored after power is disconnected from the unit.
Storing EDID Data
1. Connect an HDMI cable from the
HDMI OUT
port on the AT-HDR-SW-51 to the HDMI input on the display,
containing the EDID to be stored.
2. Log in to the web server.
3. Click
EDID
in the menu bar.
4. Locate the
EDID Saved
section.
5. Click the drop-down list, next to the memory location to be used, and select
Output 1
from the drop-down list.
Refer to the next page for more information.
HDMI
AT-HDR-SW-51
Display with EDID data
to be captured
AT-HDR-SW-51
POWER
INPUT
HDMI 1
HDMI 2
HDMI 3
HDMI 4
HDMI 5