31
30
User manual
Pandora DXL-1820L/1830L service-security system
Level 10 Configuring system settings via the wireless interface 2,4 GHz
To change the configuration of the system using a wireless interface 2,4 GHz, enter programming
level 10, the system will confirm the entering with red flash of LED indicator. The system will await
a wireless connection from the computer for 2 minutes. If the waiting time limit has expired and the
system was not connected to the computer, it will exit this level.
Level 11 Programming validator code of immobilizer (Pin to Drive)
1. Select the button to set the secret validator code of immobilizer.
To do this, enter level 11 of programming and press the selected button (e.g. wheel ‘volume up’
button), LED indicator will confirm input with orange flashes. If there are no orange flashes when any
button is pressed, then this button is not recognized by the system, select a different button. After the
button was chosen, press VALET button. Security system will memorize the last pressed button (which
was pressed before VALET button) as a button to enter PIN-code of immobilizer and will await input
of the first digit of PIN-code.
2. Program the immobilizer deactivation PIN-code.
Enter the first digit by pressing the previously selected button (pauses between presses must be
no more than 1 second). The base unit will confirm entering with red flash of LED indicator.
Input the second (third, fourth) digit by pressing the previously selected button. The base unit will
confirm entering with red flash of LED indicator.
Input the required number of digits (up to 4) and then press VALET button. The system will
confirm receiving of the secret validator code with long red flash of LED indicator and will expect for
confirmation of PIN-code.
3. Confirm the immobilizer deactivation PIN-code.
Input PIN-code again similarly to the programming procedure and press VALET button. The
system will confirm correct PIN-code with red and green flashes of LED indicator and will memorize
PIN-code, then will proceed to the programming mode awaiting level input. Incorrect confirmation
is indicated with long red flash of LED indicator, after that the system will return to a programming
mode.
4. Disarming via validator code.
The system can be disarmed by entering validator code using programmed button. It can be done
via a CAN-bus readable button (list of supported buttons can be viewed in status and command table
in AlarmStudio) or via any other button connected by analogue to ‘Code immobilizer (validator)’ input
programmed in the table of system inputs in AlarmStudio.
For example:
- when function is active, valuables can be left in the car;
- the system can be armed via VALET button; press and hold VALET button no less than 3 seconds,
the system will be armed in 30 seconds and locks will be closed;
- the system can be disarmed by entering validator code via open trunk button, after that locks
will be opened.
5. Additional authorization by entering validator code.
Validator (code immobilizer) is an additional car protection measure. Validator operation activates
all blocking relays (both analogue and digital ones).
To activate this function, enable ‘Switching off blockings only after entering validator code’. The
function will be activated automatically in 20 seconds after engine start and immediately when
arming.
When engine starts, the system awaits validator code input. If code was not entered, the system
will activate all blocks via programming logic (on engine start, on moving automatic transmission
selector/switching off handbrake, on movement start).
When maintenance mode is active, validator will be deactivated.
To switch on maintenance mode:
- switch on the ignition;
- place the tag in radio coverage zone (if immobilizer/Antihijack is enabled);
- enter validator code;
- enable maintenance mode via the remote or by dialing DTMF command
551*
and code from
the owner’s card.
To switch off maintenance mode via validator code:
- switch on the ignition;
- place the tag in radio coverage zone (if immobilizer/Antihijack is enabled);
- enter validator code;