INSTALLATION MANUAL FOR MODEL E-220
page 4
CEILING STRUCTURE
HOOD SUPPORTS
FALSE CEILING
4 – PREPARING THE HOOD FOR INSTALLATION
Let the Ø150 extraction conduit drop down from the false ceiling (This conduit should be connected
to the extraction conduit of the premises equivalent to Ø150 mm) and leave it hanging about
If there is surplus flexible conduit (If on taking it out it projects more than 30 cm) the surplus should
be cut off and removed, so as to avoid undesired bends in the conduit installation.
Install the accessory supplied with the hood to convert the rectangular 100 x 180 section to Ø150.
And prepare the mains cable for connection.
WARNING! To avoid air leaks or the conduit detaching, make sure the joints of the conduit with
the adaptor are well sealed, once fitted, seal with adhesive aluminium tape or ties.
CONVERTER FROM RECTANGULAR
CROSS-SECTION TO Ø150
30 cm down.