***In high-powered motor systems, V2300 and V2500, the minimum distance between hood and
motor must be 4m, with between 4 and 6m recommended. If it is fitted any nearer, this may cause
problems with high noise levels. It is also recommended that motors of this type be fitted with a
SEC soundproof flue (not included as standard, optional, consult distributor).
EXTERNAL Motor Version
V.1200
V.1400
V.1800
FALSE
CEILING
FALSE
CEILING
FALSE
CEILING
Flue diameter in mm
EXT - Ø150
EXT - Ø150-200
EXT - Ø200
Aspiration UNE-EN-61591
min. /max.. (m³/h)
280/1000
320/1173
300/1500
Noise level UNE-EN 60704-2-13
Min. / Max Lp (dBA)
45/62
41/57
45/69
Motor power consumption in watts
265W
355W
500W
Recommended Ducting instalation
(maximum)
Available on Type 1.
Up to 5 lineal
meters,
max distance from
hood to motor 2m
without elbows
Up to 11 linear m.
Max distance from
motor to Hood 4 m.
Available on Type 1.
Up to 9 lineal
meters,
max distance from
hood to motor 4m
without elbows
EXTERNAL Motor Version
V.2100
V.2500
FALSO
TECHO
FALSO
TECHO
Flue diameter in mm
EXT - Ø200
EXT - Ø200
Aspiration UNE-EN-61591
min. /max.. (m³/h)
380/1716
380/2100
Noise level UNE-EN 60704-2-13
Min. / Max Lp (dBA)
55/69
56/70
Motor power consumption in watts
330W
280W
Recommended Ducting instalation
(maximum)
up to 11 linear m.
Max distance from
motor to Hood 4 m.
Recommended
minium distance
from hood to motor
is 4 m.
It is advised the use
of SEC ductwork
(optional)
Minimize number of curves along the ducting, since each one significantly reduces airflow capacity:
For Ø 150mm 90º equals 1 linear meter
For Ø 200mm 90º equals 2,5 linear meter
Ex. Before 2 x 90º, total ducting length for 3 linear meters results on Ø 150 mm 5 meters
Ex. Before 2 x 90º, total ducting length for 3 linear meters results on Ø 200 mm 8 meters