4.4.2- Alarm Messages
In the following cases, the chlorinator shuts down and the alarm and acousti c alarm
LED is acti vated (automati c reset once the fault is solved):
“NO WATER FLOW”
Excess gas in the
electrolysis cell. It
may have occurred
because the pump has
shutdown. The gas is
hydrogen gas which is
highly fl ammable.
The piping should be drained to eliminate
gas or accumulated water. Check the
pump
Sensor cable of the cell
is incorrectly connected
or broken
Check the sensor cable (white cable)
Cell sensor is dirty
Clean. See maintenance
No water fl ow
Check the water system
“SHORT CIRCUIT”
The cell is incorrectly
connected
Check wiring
Metal body in the cell
Turn off the equipment and remove the
metal body from the plates
“OPEN CIRCUIT”
Cell is incorrectly
connected
Check the cell connecti on and ensure that
cables and connecti on terminals are in
good conditi on.
Cell is damaged or
completely worn down
Check the conditi on of the cell electrodes,
and replace it if any damage is observed.
Swimming pool water
with very low salt
concentrati on
Ensure that the water has salt and that it
is dissolved
“Chl. error”
Chlorine probe is
incorrectly connected
or damaged
Check the cabling of the probe and the
probe itself. Check 5.1. It can work in
manual mode if necessary
Water contains very low
redox potenti al
Leave the equipment to chlorate in
manual mode for at least 2 hours. Check
the chemical balance of the water.
(appendix 1)
The equipment does
not have a probe and is
in “automati c mode”
Install a Redox or Free Chlorine probe, or
confi gure “manual” mode