28
Troubleshooting
Please check the common problems listed in this table before seeking professional
help.
If none of the tips provided here help, if you are dealing with a problem not listed here, or if
you are otherwise uncertain, contact your retailer for more information.
Phenomenon
Cause/measure
Reference
page
The [STATUS]
indicator stays off
●
Is the repeater being powered?
¨
¨
Make sure that the repeater is connected to
the USB power adaptor.
24
The [STATUS]
indicator lights red
●
A communication error with the center module
has occurred.
¨
¨
Register the ID of the repeater on the center
module.
15, 25
The [STATUS]
indicator blinks red
●
Repeater registration has failed.
¨
¨
Confirm that the center module is in repeater
registration mode, then press and hold the
[ID REG] button on the repeater to register
the ID.
15, 25
The [STATUS]
indicator blinks orange
or green
●
Immediately after turning on the power of the
repeater
Searching for the center module.
¨
¨
Wait until the repeater connects with the
center module.
●
If a repeater is operating
The signal reception from the center module is
poor.
¨
¨
Check whether there are increased obstacles
between the repeater and the center module.
If the situation does not improve, consider
changing the location for installing the
repeater.
15, 19
WX-CR480P_PUQX1029ZAV1_OI_en-fr.indb 28