19
●
Administrator Authorization
1. Press the CAM/SET button while [SEtUP] is displayed.
The [- - - - -] prompt appears.
2. Enter a password with the numeric buttons, then press
the CAM/SET button.
The default setting is [12345].
3. [SPEED] appears when the right password is entered. If
password entry failed, the menu returns to [- - - - -].
Notes:
• We recommend that you register a new password dif-
ferent from “12345” in [SUSrP], and note down the reg-
istered password for future reference.
• Powering up the controller while holding down numeric
buttons 2, 4 and 5 simultaneously will reset the pass-
word to “12345”. Remember that this procedure also
resets all other menu parameters to the default settings.
●
Baud Rate
In this menu, the communication speed (bps: bits per sec-
ond) is selected. The communication speed should match
that of the other units connected in the communication
chain.
1. Display [SPEED] and press the CAM/SET button twice.
2. Select a parameter entering a bracket-enclosed num-
ber, e.g., (3), moving the joystick right and left, or
pressing the [+] and [–] button.
The default setting is 19 200 bps.
(1) 2 400:
2 400 bps
(2) 4 800:
4 800 bps
(3) 9 600:
9 600 bps
(4) 19 200:
19 200 bps
Note:
Selecting a slower rate (e.g., 2 400 bps) will
delay the response time (e.g., the time until an acti-
vated alarm is reset).
3. Press the CAM/SET button to validate the selection.
4. Press the ESC button to go back to the previous menu.
●
Parity
In this menu, the parity check mode is selected.
1. Display [PrtY] and press the CAM/SET button twice.
2. Select a parameter with the joystick.
The default setting is None.
n:
None
E:
Even parity
3. Press the CAM/SET button to validate the selection.
4. Press the ESC button to go back to the previous menu.
●
Wait Time
In this menu a wait time is selected. The controller will
retransmit data when there is no response during the speci-
fied wait time.
1. Display [LJAit] and press the CAM/SET button twice.
2. Select a parameter with the joystick.
The default setting is Off.
(1) OFF:
Off, no retransmission of data
(2) 100:
100 ms
(3) 200:
200 ms
(4) 400:
400 ms
(5) 500:
500 ms
(6) 1 000:
1 s
3. Press the CAM/SET button to validate the selection.
4. Press the ESC button to go back to the previous menu.
The following two menus should be maintained in the
default condition.
●
Controller Unit-Group Address
[CU-gr] appears on the Setup menu, but leave the
default as it is.
●
System Unit-Group Address
[SU-gr] appears on the Setup menu, but leave the
default as it is.