Direct mounting
If the camera is directly mounted on a
wall/ceiling, align the camera mounting posi-
tion with the position of the hole through
which the cables run and make the hole.
If no hole is made through a wall/ceiling and
open wiring along a wall/ceiling is used,
process the cover so that the cables can be
run through the side of the cover.
11
Installations and Connections
The following installation should be made by qualified service personnel or system installers.
■
Preparations
Important:
• Procure 4 mounting screws according to the material of the installation area. In this case,
wood screws and nails should not be used.
Recommended tightening torque is as follows.
M4: 1.6 N·m {1.18 lbf·ft}
• Required pull-out capacity of
a single screw/bolt is 196 N
{44.1 lbf} or more.
• If a ceiling board such as
plaster board is too weak to
support the total weight, the
area shall be sufficiently rein-
forced.
• The protection sheet attached
to the dome cover shall be
peeled off after installation.
Camera fixing hole
ø4 - 4.5 mm {0.16" - 0.18"}
4.5 mm
{0.18"}
83.5mm {3.29"}
ø
146mm {5.75"}
46 mm {1.81"}
<Back/upper>
Side cable access hole
Cable access hole
for wall/ceiling
ø30 - 50 mm {1.18" - 1.97"}
●
Using a two-gang junction box
When using a two-gang junction box (4" x
4"), procure one locally that meets the
dimensions in the figure.
And then, locally procure four camera-
mounting screws suitable for the installation
surface and structure of the wall/ceiling or
two-gang junction box.
Processed section of the side
surface of the cover
Caution:
ONLY CONNECT THIS TO 24 V AC OR 12 V DC CLASS 2 POWER SUPPLY.