13 Configure the alarm settings [Alarm]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the
VMD area settings, and the alarm occurrence notification can be configured on this page.
The “Alarm” page has 3 tabs; the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
13.1 Configure the settings relating to the alarm
action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
®
page 32, page 34)
The settings relating to the alarm can be configured in this section. Refer to page 87 for further information
about the settings relating to the alarm images.
Alarm
[VMD alarm]
When clicking “VMD >>”, the [VMD area] tab of the “Alarm” page will be displayed.
[Command alarm]
Select “On” or “Off” to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a Panasonic protocol alarm from the other
cameras. When “On” is selected, alarm actions will be performed between multiple cameras.
•
Default:
Off
[Originating port number]
Select a port number to be used to receive the command alarm.
•
Available range:
1-65535
•
Default:
8181
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
13.2 Configure the settings relating to the alarm
image [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
®
page 32, page 34)
Operating Instructions
87
13 Configure the alarm settings [Alarm]