16
Installing the camera directly on the ceiling or wall.
IMPORTANT:
• Procure 3 screws (M4) to secure the camera to a ceiling or a wall, according to the material of
the installation area. In this case, wood screws and nails should not be used.
For mounting a camera on a concrete ceiling, use an anchor bolt (for M4) or an AY plug bolt
(M4) for securing. (Recommended tightening torque: 1.6 N·m {1.18 lbf·ft})
• Required pull-out capacity of a single screw/bolt is 196 N {44 lbf} or more.
• If a ceiling board such as plaster board is too weak to support the total weight, the area shall
be sufficiently reinforced.
The mounting conditions of the camera are described as follows:
Installation
place
Installation method
Recommended
screw
Number of
screw
Minimum pull-out
strength (per 1 pc.)
Ceiling/wall
(direct mounting)
M4
3 pcs.
196 N {44 lbf}
Preparations
■
Removing the enclosure
IMPORTANT:
• Remove the cover film attached to the dome
cover after the camera installation is completed.
FRYHUƄOP