-18-
Preliminary Setup
Prior to connection to the system, you need to set up a
network address for the camera by one-to-one connec-
tion with a PC.
The factory default parameters are as follows:
IP address: 192.168.0.10
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
HTTP port number: 80
1. Enter an IP address, "http://192.168.0.10" for exam-
ple, in the address bar of the browser to display
the "Main Menu" window of the WV-NS320/NS324E
camera.
2. Click the [Setup Menu] button. The authentication
dialog window appears.
3. Enter "admin" in the "User Name" input box.
According to the default setting, you need not enter
the password. The "Network Setup" page appears.
Network Cable (Cross type)
4. Set the following parameters.
Note:
Ask your system administrator about param-
eters if you are unsure.
IP Address:
Enter numbers 0 through 255 into four
sections split by dots.
Netmask:
Enter numbers 0 through 255 into four
sections split by dots.
HTTP Port:
Enter different numbers for each when
multiple cameras are connected.
DHCP (Dynamic Host Configuration Protocol):
When set to "ON", you need not input the IP
address and netmask.
DNS (Domain Name System):
Set to "ON" when
using DNS. Enter the primary address. If nec-
essary, enter the secondary address.
When set to "AUTO", the DHCP server will
automatically send you an address.
DDNS (Dynamic DNS):
Consult your system
administrator.
Note:
You can correct the DHCP setting to "OFF"
via the "Panasonic IP Setup" software or
"Camera Control" window if you have wrongly
set DHCP to "ON" in a none-DHCP/DHCP serv-
er system.
For details refer to "Setup" included in the
"Panasonic IP Setup" Software provided.
5. Click the [SET & REBOOT] button. The changed
parameters will be validated, and the camera and
the PC will restart.
Notes:
• Do not omit step 4 above to validate new
parameters.
• Wait around 5 seconds or more when execut-
ing [SET & REBOOT] button.