2-4
REMOTE
OPERATE
PROG
ALARM
RESET
NORMAL
SYSTEM
ALARM OFF
EVR
Left
Switch
Right
Switch
Mode Selection
Switch
Program
Switch
Up
Switch
Down
Switch
Set
Switch
IN
OUT
STD. CAMERA
VP CAMERA
VIDEO
CAMERA
DC12V IN
RS232C
VP/STD Camera Selection Switch
RS232C Connector
4.2. Setting Up for Remote E.V.R.
Adjustment Kit
(1). Remote E.V.R. Adjustment Kit
Fig. 4-2
(3). Installing E.V.R. Adjustment Program
8
Make a copy of following necessory files to your comput-
er from original floppy disk of the Remote E.V.R.
Adjustment Kit.
RADJ2.EXE
CW374E.SEQ
CW374E.EV2
(2). Switch Setting
8
Remove the Upper Cover.
8
Set the switch SW3 on the Board to the position as
shown in Fig. 4-3.
Fig. 4-3
8
Set the VP/STD.Camera Selection Switch on the Rear
Panel to STD CAMERA position.
8
Set the Mode Selection Switch on the Front Panel to
ALARM OFF position.
<Rear>
<Front>
Board
SW3
ON
<SW3>
<SW3>
1
2
3
4
Select switch #2 to ON (PAL) position.
#
ON
OFF
1
FIX
2
PAL
NTSC
3
FIX
4
FIX
4. Connection and Setting Up for
Adjustment
4.1. Connection
8
The Fig. 4-1 shows the connecting diagram for the
Adjustment Procedure.
Fig. 4-1
Test Chart
Lens
Floppy
Disk
Underscanned
Colour
Video Monitor
Remote E.V.R.
Adjustment
Kit
12 V DC
Power Supply
Unit
RS-232C
Straight
Cable
RS-232C
DC12V
IN
Personal
Computer
75
Ω
CAMERA
Vectorscope
CAMERA
IN
VIDEO
OUT
Video
Output
Cable
Power
Cable
(For WV-CW374E)
220-240 V AC
(For WV-CW370)
24 V AC or 12 V DC
Power Supply Unit
8
Connect the probe of the Oscilloscope or Frequency
counter at the desired Test Point in each adjustment step.