(10.2). 5 100°K B Gain Adjustment
Test Point:
Video Output Cable
8
Keep the Colour Temperature at 5 100°K.
8
Adjust data with the ARROW keys so that the Yellow gain
becomes 120 % ± 5 %.
8
Repeat adjusment steps (10.1) and (10.2) until both
Chrominance phase and gain are adjusted to proper posi-
tion as shown in Fig. 5-12 and Table 5-3.
Fig. 5-12
Table 5-3
Minimize
Chrominance
Level
Fig. 5-13
8
Press ENTER key for next adjustment.
(11). High light Chroma Clip Adjustment
Test Point:
Video Output Cable
Adjust:
RAM (801F)
8
Return the Colour Temperature from 5 100°K to 3 200°K
by removing the Colour Temperature Conversion Filter
from the Lens.
8
Aim the Camera at the White Chart or White Paper.
8
Connect the terminated Oscilloscope with 75
Ω
to the
Video Output Connector.
8
Adjust data with the ARROW keys so that the false
chrominance level becomes minimum as shown in Fig. 5-
13.
Note: The Data of 801F should be adjusted from FF, the first
minimum point of the false chrominance signal is
adjusting point.
(12.1). Line Lock Phase Coarse Adjustment
Test Point:
Video Output Cable
Live (Brown) of the Camera Power Cable
8
Change the Colour Temperature from 3 200°K to 5 100°K
by mounting the Colour Temperature Conversion Filter
on the Lens.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the CH1 of the terminated Oscilloscope with 75
Ω
to the Video Output Cable.
8
Connect the CH2 of the Oscilloscope to the Live (Brown)
of the Camera Power Cable.
8
Connect the Ground Probe of CH2 to the Neutral (Blue)
of the Camera Power Cable.
8
Adjust data with the ARROW keys so that the Decay
point of V SYNC signal gains 2H ± 2H from the zero-
cross point of the AC Power Line Input Waveforms as
shown in Fig. 5-14.
8
Press the ENTER key for next adjustment.
(12.2). Line Lock Phase Fine Adjustment
Test Point:
Video Output Cable
Live (Brown) of the Camera Power Cable
8
Keep the Colour Temperature at 5 100°K.
8
Aim the Camera at the Logarithmic Gray Scale Chart.
8
Connect the CH1 of the terminated Oscilloscope with 75
Ω
to the Video Output Cable.
8
Connect the CH2 of the Oscilloscope to the Live (Brown)
of the Camera Power Cable.
8
Connect the Ground Probe of CH2 to the Neutral (Blue)
of the Camera Power Cable.
8
Adjust data with the ARROW keys so that the Decay
point of V SYNC signal gains 2H ± 2H from the zero-
cross point of the AC Power Line Input Waveforms as
shown in Fig. 5-14.
8
Repeat adjustment steps (12.1) and (12.2) until the
Decay point of V SYNC signal gains 2H ± 2H from the
zero-cross point of the AC Power Line Input waveforms.
8
After completing the adjustment, press the QUIT (F3)
key, then the menu <SAVE CAMERA DATA TO FILE :
✽
✽ ✽
. EVR? Y/N> will be displayed.
8
Press the N key, and then press the ENTER key to finish
this adjustment procedure.
AC Power
Line Input
Waveforms
(CH2)
Video Output
Signal
Waveform
(CH1)
–
+
2H
±
2H
Zero-Cross Point
V SYNC
(NEUTRAL)
(LIVE)
Fig. 5-14