-18-
Left Button (
L
):
Moves the cursor to the left. Use
this button to select or adjust the parameters of the
selected item. The parameter changes each time
this button is pressed.
Set Button (
I
):
Executes selections and displays a
submenu for an item with
N
mark.
END:
Close Setup menu.
RET:
Return to the previous menu or page.
To return to the SET UP menu.
Move the cursor to RET and press
I
. The SET UP
menu appears.
• All Reset Operation
All Reset allows you to reset all setup menu items to
the factory default settings if you are unsure about the
correct settings. Proceed as follows:
(1) Make sure that the CAM SET UP menu is not dis-
played (a camera picture is displayed).
(2) While pressing both
L
and
M
, press
I
for a
few seconds. The message ALL RESET momen-
tarily appears on the monitor.
This resets all adjustments and parameters to the
factory default settings.
• Editing the RS485 and CAM SET UP Menu
Important Notice:
• When the SET UP DISABLE appears on the bottom
line of the SET UP menu, you cannot change the
currently active settings. This is to prevent acci-
dental changing of the settings.
• Set the RS485 menu previously.
** SET UP **
CAMERA
RS485
END SET UP ENABLE
↵
↵
* RS485 SET UP *
UNIT NUMBER 1
BAUD RATE 19200
DATA BIT 8
PARITY CHECK NONE
STOP BIT 1
XON/XOFF NOT USE
WAIT TIME OFF
ALARM DATA AUTO2
DELAY TIME ---
RET
** CAM SET UP **
CAMERA ID OFF
ALC/ELC ALC
SHUTTER ---
AGC ON
SENS UP OFF
SYNC INT
WHITE BAL ATW
MOTION DET OFF
LENS DRIVE DC
RET
↵
↵
↵
** SET UP **
CAMERA
RS485
END SET UP DISABLE
↵
↵