81
■
System Status Table
The table shows the system status in real time.
1. Select a desired monitor. (Refer to p. 56 Monitor
Selection.)
2. Display "SysStat" menu. (Refer to Step 1 and 2 of p. 77
To Recall Menu Functions.)
3. Select a desired function by pressing one of the F1 to
F3 buttons.
Available buttons and functions
F1: On
Opens the SYSTEM STATUS table.
F2: Off
Closes the SYSTEM STATUS table.
F3: Blk
Changes the monitor background beween camera
images and black picture.
MON:
Monitor number
AREA:
Area number
CAM/DVR/SEQ:
<Example>
C6400001:
Unit 64, Camera 1
R6400001:
Unit 64, Recorder 1
T640010001P:
Unit 64, Area 1, Tour Sequence 1
pause
G640010001P:
Unit 64, Area 1, Group Sequence 1
pause
DEV:
Device Name
K:
System controller number with normal user oper-
ator.
S:
System controller number with super user opera-
tor.
ALM:
Alarm
EVT:
Timer event
USER:
User ID
Note:
Alarm USRID consists of alarm number and
alarm action number.
E.g. "ALM20" indicates alarm #2 and its action
#0.
PRI:
User priority
4. To display the next page, press the + button.
To display the previous page, press the – button.
Notes:
• To display the first page of table, press the + but-
ton while holding down the SHIFT button.
• To display the last page of table, press the – button
while holding down the SHIFT button.
5. To exit the SYSTEM STATUS table, perform either of the
following.
• Select a camera. (Refer to p. 56 Camera Selection.)
• Press the MON(ESC) button.
• Press the EXIT button.
■
Video Loss History Table
There are 100 video loss detection records stored in
chronological order in 10 pages of table.
1. Select a desired monitor. (Refer to p. 56 Monitor
Selection.)
2. Display "VL Hist" menu. (Refer to Step 1 and 2 of p. 77
To Recall Menu Functions.)
3. Select a desired function by pressing one of the F1 to
F3 buttons.
Available buttons and functions
F1: On
Opens the VIDEO LOSS HISTORY table.
F2: Off
Closes the VIDEO LOSS HISTORY table.
F3: Blk
Changes the monitor background beween camera
images and black picture.
CAM:
Logical camera number that is connected to the
system.
STATE:
Indicates video loss changes.
OK:
Video loss is recovered.
LS:
Video level is below normal and in sync.
VL:
Video level is below normal and out of sync.
HL:
Video level is above normal and out of sync.
TYPE:
Place where the video loss occurs.
S:
Video crosspoint input (Not supported)
C:
Camera control input
DATE/TIME:
Date and time when the video loss state
changes.
SysStat: 010
On Off Blk
SYSTEM STATUS PG
MON AREA CAM/DVR/SEQ DEV USER PRI
1 1 C6400001 K1 1 1
999 999 R6400001 S128 12345 1234
999 999 T640010001P S128 12345 999
999 999 G640010001P S128 12345 999
VL Hist: 011
On Off Blk
VIDEO LOSS HISTORY PG
CAM STATE TYPE DATE/TIME
6401 OK C 01/01/01 12:00
Содержание WJMPU955A - CENTRAL PROCESSING UNIT
Страница 12: ...12 This page intentionally left blank...
Страница 13: ...13 FEATURES OF WJ SX650 512 x 64 FULL MATRIX SYSTEM AND GX SYSTEM...
Страница 20: ...20 This page intentionally left blank...
Страница 21: ...21 21 21 DETAILED PRODUCT DESCRIPTION...
Страница 24: ...24 This page intentionally left blank...
Страница 25: ...25 INSTALLATIONS...
Страница 27: ...27 CONNECTION OF GX SYSTEM NTSC MODEL ONLY...
Страница 35: ...35 CONNECTION OF WJ SX650 512 x 64 FULL MATRIX SYSTEM...
Страница 41: ...41 CONFIGURATION DETAILS...
Страница 53: ...53 OPERATING PROCEDURES with WV CU950...
Страница 83: ...83 APPENDIX...