13
●
How to Mount
1.
Turn off the power of the unit and detach the plug from
the outlet.
When not turning off the power, open the front cover
and turn off the HDD POWER switch.
2.
Remove the six rubber feet by removing the six screws
from the bottom of the unit
3.
Fix the Rack Mounting Brackets (supplied) on both
sides of the unit with the four screws (M4X10, supplied).
4.
Install the unit in the rack securing it with four screws
(M5x12, not supplied).
5.
Turn on the power of the unit.
When the HDD POWER switch is turned off, turn it on
and attach the front cover as it was.
Cautions:
• Make a space of 1U (44 mm) between the units for ven-
tilation, and install them in the rack as low as possible.
• Keep the temperature in a rack below 45 °C (113 °F).
• Install a fan in the rack when the ambient temperature is
above 30 °C (86 °F).
• Do not block the ventilation openings or slots on the
cover to prevent the unit from overheating.
Remove 6 screws
M4X10 (Supplied)
Rack Mounting Bracket (Supplied)
M5X12 (Not supplied)