21
Connection example for emergency recording
When the external switch is turned on, emergency recording will start.
Recording time and recording rate for emergency recording differ according to the settings of "Emergency rec." on the setup
menu. (Refer to the Operating Instructions.)
C1
D2
(Emergency recording input)
(Signal ground)
External switch
C12
D11
Connection example for external recording switching
When the external switch is turned on, the recording program will be switched and recording will start.
The recording program can be set by selecting "Ext." for "Time table" of "Schedule" on the setup menu. (Refer to the Operating
Instructions (PDF) for further information.)
D4
(Signal ground)
External switch
(External recording mode switching input)
C1
C12
D11
Connection example 1 for the auto adjustment time function
When "Auto time adjustment" found in "Date & time settings" under "Date/Language" on the setup menu is set to
"Master".
"Time adjustment output" becomes available and the clock of this recorder will be applied to other devices.
The time adjust output signal will be supplied from C5 terminal to other recorders at the time set for "Activation time" of "Time &
date" under "Basic" on the setup menu.
(Signal ground)
(Time adjustment I/O)
C5
C11
D1
D12
Terminal of the other device
Signal ground
Sensor input
Alarm input
Alarm reset input
Series recording input
Time adjustment input
Signal ground
Alarm output
Alarm reset output
Alarm recording
During recording
Disk
Buzzer output
System error output
Temperature warning output
Time adjustment output
Series recording output
Front panel
LED monitor
output
3
Connections
(continued)