63
The minimum settings required to operate the recorder such as the language, time & date, network and schedule, etc. can be
configured on the "Quick" page. The "Quick" page has only the [Setup] tab.
First, configure the minimum settings on the "Quick" page, and to configure more advanced settings, go to each setup menu.
Configure the minimum settings required to operate the recorder [Quick]
[Language]
Select the desired language of the setup menu.
Japanese/English/Français/Español/Deutsch/Italiano/
Russian
Default:
English
[Time & date]
Set the current time & date.
Year, month, day, time and minute are set.
When using a mouse, it is possible to set by clicking the
icon.
After completing the settings, click the [OK] button.
The second will be set to "00" when the [OK] button is
clicked.
■
REC setup
[Resolution]
Select the resolution for images to be recorded from the fol-
lowing.
Frame 3D On:
High resolution with the motion blur
compensation
Frame 3D Off:
High resolution
Field:
Standard resolution
Default:
Field
Important:
• The selected resolution will be applied to "Resolution" of
the following of the setup menu.
• "Resolution" under the [Emergency rec.] tab on the
"Basic" page
• Resolution" of program 1-4 on the [Program] tab
under the "Schedule" page
■
Schedule
Create recording programs by designating day of the week
when recording is to be performed, image quality and
recording rate.
When selecting the [OK] button after creating a recording
program, the created recording program will be applied to a
program and time table on the "Schedule" page of the setup
menu.
Up to 4 recording programs can be created. (Program 1 to
4)
[Mode]
Select a day of the week.
When "Off" is selected, the schedule will be invalidated.
Off/Mon/Tue/Wed/Thu/Fri/Sat/Sun/Mon - Fri/Mon - Sat/
Mon - Sun/Daily
Default:
Daily (Program 1 only)
[Start]
Set the start time of the time zone.
00:00 to 23:45 / --:-- (Available in steps of times)
Default:
Daily (Program 1 only)
[End]
Set the end time of the time zone. Set the end time at least
15 minutes later than the start time.
00:15 to 24:00 / --:-- (Available in steps of times)
Default:
24:00
[Quality]
Select the image quality for live images from the following
XF (Extra Fine):
Extra quality
SF (Super Fine):
Super high quality
FQ (Fine):
High quality
NQ (Normal):
Standard quality
EX (Extended):
Low quality (for long recording)
Default:
FQ