Secure fan body
Flange
Joist
1
2
Plug connector
Receptacle
Machine screw (M4X8)
2 self-drilling screws
WARNING
CAUTION
Disconnect power supply before working on unit.
Routine maintenance must be done every
year. Please wear gloves during the
cleaning work.
Do not immerse motor in water when
cleaning. Do not soak resin parts in
water over 140° C (60
° F
).
Never use gasoline, benzene, thinner or
any other such chemicals for cleaning the
ventilating fan.
Remove grille
1
2
1
Gloves
Slot
Grille
Mounting spring
Remove grille by pulling down one mounting spring.
Disconnect the wire from the receptacle, then pull down the other mountain spring.
1
2
Plug connector into receptacle and secure
fan body to adaptor by using the machine
screw (M4X8).
When the flange overlaps Flex-Z Fast™
bracket, secure it by using 2 self-drilling
screws.
Follow the steps 7 to 8 in INSTALLATION
(RETROFIT)
3
Mounting spring
LED lamp wire
Receptacle
2
Drywall
10
MAINTENANCE (CLEANING)
INSTALLATION (NEW CONSTRUCTION) (CONTINUED)