PROGRAMMABLE DISPLAY WHA1 Advanced Model
7
3 Installation
3.1 Installation Environment
In order to meet the front panel protection classifications, proper installation procedure must be
followed:
・
the borders of the cutout must be flat
・
screw up each fixing screw until the plastic bezel corner get in contact with the panel.
・
the cutout for the panel must be of the dimensions indicated in this manual.
The IP66 is guaranteed only if:
・
max deviation from the plane surface to the cut-out:
≦
0.5 mm
・
thickness of the case where is mounted the equipment: from 1.5 mm to 6 mm
・
max surface roughness where the gasket is applied:
≦
120 μm
A
:
WHA1 Advanced Model
B
:
Installation cut-out
3.2 Installation Method
Place the fixing brackets contained in the fixing kit.
Tightening torque: 1.3N
・
m or screw each fixing screw until the bezel corner gets in contact with the
panel.
(Notes)
・
The equipment is not intended for continuous exposure to direct sunlight.
・
The equipment is not intended for installation in contact with corrosive chemical
compounds.
・
Do not use tools of any kind (screwdrivers, etc.) to operate the touch screen of the panel.
・
The vents in the panel casing must not be obstructed.