Страница 1: ...PROGRAMMABLE DISPLAY WHA1 Series User s Manual WUME WHA1 01 2020 12 panasonic net id pidsx global ...

Страница 2: ...ion use this product at the values less than the maximum of the characteristics and performance that are assured in these specifications Do not dismantle or remodel the product It could cause excessive exothermic heat or smoke generation Do not touch the terminal while turning on electricity It could lead to an electric shock Use the external devices to function the emergency stop and interlock ci...

Страница 3: ...hecking and cleaning of infection by computer virus or malicious program is performed periodically It has the ability to use unencrypted communications FTP HTTP SMTP PLC communications etc Please make sure that a third party cannot easily connect to the network used by this product Use HTTPS when accessing this product through a web browser Also be sure to close all browsers after accessing it Do ...

Страница 4: ...ructions and the user s manual and understand their contents in detail to use the product properly Types of Manual There are different types of user s manual for the WHA1 series as listed below Please refer to a relevant manual for the unit and purpose of your use The manuals can be downloaded on our download center https industrial panasonic com ac j dl_center Unit name or purpose of use Manual n...

Страница 5: ...Supply 3 2 3 Grounding 4 2 4 Serial Port 4 2 4 1 Wiring Example of Serial Port 5 2 5 Ethernet Port 6 2 6 DISPOSE OF BATTERIES 6 2 6 1Detaching method of batteries 6 3 Installation 7 3 1 Installation Environment 7 3 2 Installation Method 7 4 Specifications 8 4 1 1 General Specifications 8 4 1 2 Performance Specifications 9 4 1 3 Function Specifications 10 4 1 4 Interface 11 4 2 Dimensions 14 4 2 1 ...

Страница 6: ...d to the panel surface the LCD panel may be damaged Power Supply Twist the wires of the power supply The unit has sufficient noise immunity against the noise generated on the power line However it is recommended to take measures for reducing noise such as using an isolating transformer before supplying the power And it is recommended to take measures such as installing a ferrite core Allocate an i...

Страница 7: ...e the power is on Communication may be stopped It is necessary to restart the power supply to recover The data saved in the USB memory may be lost in the following cases We assume no responsibility whatsoever for the lost of saved data 1 When a user or third party used the USB memory incorrectly 2 When the USB memory was affected by any static electricity or electrical noise 3 When the USB memory ...

Страница 8: ...ou can download from our website https www3 panasonic biz ac e index jsp Member registration is necessary free of charge 1 3 Remote monitoring Tool This software is used for remote monitoring tool Item name Required OS Hard disk capacity Remarks Tool Software xAscender Client Windows 10 It is installed at the same time you install xAscender Suite Notes xAscender cannot start normally due to the co...

Страница 9: ...e the protection seal on the rear 3 USB Port 1 Port 4 Ethernet Port 0 5 Ethernet Port 1 6 Power 7 Serial Port 2 1 2 AWHA1C070 AWHA1C101 AWHA1C156 AWHA1C215 No Description 1 Do not use Do not remove the protection seal on the rear 2 SD Card Slot 3 Power Supply 4 Ethernet Port 0 5 Serial Port 6 Ethernet Port 1 7 Ethernet Port 2 8 USB Port 2 Ports ...

Страница 10: ...ouble or reinforced insulation The suggested wiring for the power supply is shown in figure All the electronic devices in the control system must be properly grounded Note 1 If the power supply is incorrect the internal electronic components may be damaged Note 2 Ensure that the power supply has enough power capacity for the operation of the equipment Note 3 Please use the SELV Safety Extra Low Vo...

Страница 11: ...appropriate interface in the programming software To operate in RS485 pins 1 2 and 3 4 must be connected externally To connect to the serial port use a connector provided with the unit Suitable wires Size Nominal cross sectional area Rated temperature AWG24 to 20 0 2 to 0 5mm2 105 or more Pin No Pin name Serial RS 232C RS 422 RS 485 1 RX RXD RxD RXD RXD 2 TX TXD TxD TXD TXD 3 CTS RXD CTS RXD RXD 4...

Страница 12: ...ed Model Fanction Signal name Pin No Pin name Send data SD 1 RX RXD Receive data RD 2 TX TXD Signal ground SG 3 CTS RXD 4 RTS TXD 5 5V output 6 GND 7 8 SHIELD RS 422 Communication PLC RS 422 port WHA1 Advanced Model Fanction Signal name Pin No Pin name Send data SD 1 RX RXD Send data SDー 2 TX TXD Receive data RD 3 CTS RXD Receive data RDー 4 RTS TXD 5 5V output 6 GND 7 8 SHIELD RS 485 Communication...

Страница 13: ...the connector Alternatively use a nipper to cut the cable 3 The battery is located on the back of the board as shown in the illustration using the nipper remove the battery from the board AWHA1C070 AWHA1C101 AWHA1C156 AWHA1C215 1 Remove the main unit case mounting screws and remove the case 2 The battery is located on the back of the board as shown in the illustration using the nipper Green Yellow...

Страница 14: ...ut 0 5 mm thickness of the case where is mounted the equipment from 1 5 mm to 6 mm max surface roughness where the gasket is applied 120 μm A WHA1 Advanced Model B Installation cut out 3 2 Installation Method Place the fixing brackets contained in the fixing kit Tightening torque 1 3N m or screw each fixing screw until the bezel corner gets in contact with the panel Notes The equipment is not inte...

Страница 15: ...umidity 5 to 85 RH at 25 non condensing Vibration resistance 5 to 9 Hz 3 5 mm single amplitude 9 to 150 Hz Acceleration 9 8m s2 1 G Shock resistance 490m s2 50 G 11 ms 3 times in the X Y Z directions EU Directive applicable standard EMC Directive EN61000 6 2 EN61000 6 4 RoHS Directive EN50581 Protective construction Note 2 Front panel IP66 Initial value evaluated by us Rear IP20 Pollution degree e...

Страница 16: ...space RAM 512MB 1GB 2GB Memory 4GB 4GB 8GB Project memory 240MB User memory 512MB RTC Backup Accuracy RTC 100ppm or less at 25 Note 3 Function Clock Calendar Period Lithium batteries secondary batteries 3 months Requires 48 hours of power at 25 Note 4 Other Buzzer Yes Note 1 On the LCD panel bright spots points always lit or black spots points always unlit may appear or the uneven brightness flick...

Страница 17: ...asic text numerics Button Meter Switch Light Media Icon Custom etc Main functions Trends Reports Alarms Scheduler Database Data Transfers Recipe Keypads Web Server etc Refer to xAscender Studio User s Manual Basic Through function Communication between our PLC and a computer is available by connecting the computer to the Ethernet port and the PLC to the COM port Note 1 Maximum allowable number var...

Страница 18: ...none even odd Stop bit bit 1 2 1 2 Transmission distance Total length Max 15m Baud rate 19 200 bps Max 500m Baud rate 115 2 kbps Terminal resistance value No Termination Note 2 Protocol Refer to xAscender Studio User s Manual Communication Connector Connector provided with the unit Note 1 Depend on PLC Please check with the actual devices when some commercial devices with RS485 interface are conne...

Страница 19: ...1CH 2CH Communication standard High Speed USB 2 0 Host Controller Connector shape USB Type A Transmission speed 480Mbps High Speed Maximum current Max 500mA Note 1 Take care of handling of the connector not to add an excessive static electricity on the metal part of the connector Note 2 The format of the external memory should be in FAT32 or FAT The max number of files inside external memory depen...

Страница 20: ...wer supply of the HMI unit was turned off while data was being read written or deleted to from the SD memory card It is recommended to save important data in another media for backup Formatting an SD memory card Download formatting software for SD memory card on the following website Website https www sdcard org downloads formatter Note 1 Industrial or business use SD memory cards SLC type are rec...

Страница 21: ...Y WHA1 Advanced Model 14 4 2 Dimensions 4 2 1 AWHA1C050 Model No A B AWHA1C050 136mm 5 35 96mm 3 78 Model No L H D T AWHA1C050 147mm 5 78 107mm 4 21 52mm 2 04 8mm 0 31 Unit mm inch Tolerance except T 1mm T Tolerance 0 5mm ...

Страница 22: ...7 32 AWHA1C156 411mm 16 18 256mm 10 00 AWHA1C215 541mm 21 30 336mm 13 22 Model No L H D T AWHA1C070 187mm 07 36 147mm 05 79 45mm 01 77 8mm 0 31 AWHA1C101 282mm 11 10 197mm 07 75 52mm 02 04 8mm 0 31 AWHA1C156 422mm 16 60 267mm 10 50 56mm 02 20 8mm 0 31 AWHA1C215 552mm 21 73 347mm 13 66 56mm 02 20 8mm 0 31 Unit mm inch Tolerance except T 1mm T Tolerance 0 5mm Cut out ...

Страница 23: ...e simultaneously with the transfer of the application project created by xAscender Studio There are two options to transfer a xAscender Studio application project to a HMI device Ethernet Connect the HMI device to the computer with an Ethernet From xAscender Studio select the menu Run Download to target You may have to ensure that the proper firewall policy has been configured in the computer to a...

Страница 24: ...ngs in Config OS mode via tap tap procedure on HMI or open web browser to https HMI IP address machine_config and select the Management section Expand the component to update and select Update On the opened dialog click Browse Image then select the xxx mainos xxx tar gz file Click then on Browse MD5 and select the xxx mainos xxx tar gz md5 file At the end of the component update restart HMI and le...

Страница 25: ...HMI screen both menu and content of selected item may be shown on screen at the same time or not System Settings has two modes of operation User Mode xAscender HMI Runtime is running or the HMI device is in factory default status System Mode xAscender HMI Runtime is not running or the HMI device has a software failure System Mode includes all options available in User Mode and additionally include...

Страница 26: ...FIG OS to boot in System Mode System Settings includes options for basic settings of the device Language Configure language used for System Setting menu only System Show informations about platform status and timers like System on time backlight on time Logs Enable persistent log for BSP and allows exporting it Date Time Change the device date and time including time zone and NTP Server Network Co...

Страница 27: ...PROGRAMMABLE DISPLAY WHA1 Advanced Model 20 Revision History Manual no Date Record of Changes WUME WHA1 01 Dec 2020 1st edition ...

Страница 28: ...Panasonic Industrial Devices SUNX Co Ltd 2020 WUME WHA1 01 December 2020 Panasonic Industrial Devices SUNX Co Ltd https panasonic net id pidsx global Please visit our website for inquiries and about our sales network ...