47
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Accessories
Aquarea Heat Pump cylinders
Aquarea Slimline HP cylinder
ASLPAN180HPSL
Capacity – total volume
litres
180
Volume heated by IH
litres
170
Dedicated solar volume
litres
–
Standing heat loss rate
kWh/24h
2 .01
Weight – empty/full
kg
33/213
Pressure regulating valve setting
bar
3
Expansion relief valve setting
bar
4 .75
Temperature setting (P&T valve)
°C
95
Pressure setting (P&T valve)
bar
6 .0
Expansion vessel size (volume)
litres
18
Expansion vessel initial charge pressure
bar
3
Height
A
mm
1,790
Diameter
B
mm
475
22 mm secondary return
C
mm
–
22 mm compression cold feed
D
mm
283
P&T valve
E
mm
1,535
22 mm solar return
F
mm
-
22 mm solar flow
G
mm
-
28 mm primary return
H
mm
275
28 mm primary flow
I
mm
1,545
HP control thermostat
J
mm
628
Dual CT & OHT pocket
K
mm
628
Solar sensor pocket – 1 top
L
mm
-
Solar sensor pocket – 2 bottom
M
mm
-
3 kW immersion heater height
N
mm
207
Surface area of solar heater coil
m²
-
Solar coil pressure loss
1
bar
-
Primary heat exchanger surface area
m²
3 .01
Primary heat exchanger thermal rating
1
kW
32 .8
Primary heat exchanger pressure loss
1
bar
0 .018
Heat up time from 15 °C to 60 °C
2
min
33
Recovery time after 70 % draw-off
2
min
21
1
Measured at 0.25 l/s primary flow rate
2
Measured at 0.25 l/s primary flow rate and at 82 °C flow temperature
Table 2
H
N
A
C
I
D
K
J
E
3,00°
P & T
33,00°
Cold Feed
62,00
°
Stat 2
Immersion
52,00°
Sec. Rtn
@
37,00°
Coil Connections
Note
Not all models – see table 2.
Recovery times based
on Primary Coil/I.H. duty
(ie. assumes the boiler
output is adequate).
All connections are supplied
with compression fittings for
direct connection to copper
pipework .