39
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Monobloc system
Easy operation
Easy maintenance
and assembly
• control is by means of a wired controller inside the building
(15 m cable)
• simple programming via the controller
• Aquarea monobloc unit is equipped for safety reasons with
FI-circuit breakers:
- 2 FI RCD circuit breakers for 5, 6 and 9 kW units
- 3 FI RCD circuit breakers for 12, 14 and 16 kW units
only required on Phase-out models C,D & E series
• Monobloc system, no special space requirement inside the building,
no refrigerant connections
• easy opening of the unit for maintenance work
Supply water
temperature (°C)
Outside
temperature (°C)
Cooling mode
1
Maximum
20
43
Minimum
5
16
Heating mode
Maximum
55 / 65
2
35
Minimum
25
-20
3
1
valid for models with cooling mode
2
valid for Aquarea HT
3
If the outside temperatures drop below the specified value, the heating
capacity decreases significantly. This can lead to the shutdown of the unit
due to internal safety functions.