100
Aquarea air / water heat pump – design handbook 07 / 2014
Project Design
Hydraulics
Pumping height
Pump characteristic curve of the high-efficiency water circulation pump with differential
pressure control for the Aquarea heat pump units WH-SDF03E3E5, WH-SDF05E3E5,
WH-SDC03E3E5 and WH-SDC05E3E5
Pump characteristic curve of the high-efficiency water circulation pump with differential
pressure control for the Aquarea heat pump units WH-MDF06E3E5, WH-MDF09E3E5,
WH-MDC09E3E5,
WH-SXF09E3E8 and WH-SXF12D9E8 (Phase-out models)
70
60
50
40
30
20
10
0
Circulation rate [l
/
min]
Pump operating head [kPa
]
0
10
20
30
40
50
6
&
7
5
4
3
2
1
70
60
50
40
30
20
10
0
Circulation rate [l
/
min]
Pump operating head [kPa
]
0
10
7
6
5
4
3
2
1
20
30
40
50
Pump delivery head of
high-efficiency pumps
with differential pressure
control
Properties of the standard water circulation pump for the Aquarea heat pumps,
9 kW three phase and 12, 14 and 16 kW single phase and three phase.
90
80
70
60
50
40
30
20
10
0
Circulation rate [l
/
min]
Pump operating head [kPa
]
0
10
20
30
40
50
60
70
Pump speed 3
Pump speed 2
Pump speed 1