46
Aquarea air / water heat pump – design handbook 07 / 2014
Products, functions and technical data
Accessories
Aquarea Heat Pump cylinders
Aquarea HP cylinder
ASLPAN180HP
ASLPAN300HP
ASLPAN400HP
Capacity – total volume
litres
180
300
400
Volume heated by IH
litres
113
195
270
Dedicated solar volume
litres
65
105
130
Standing heat loss rate
kWh/24h
1 .48
2 .04
2 .82
Weight – empty/full
kg
33/213
49/349
61/461
Pressure regulating valve setting
bar
3
3
3
Expansion relief valve setting
bar
4 .75
4 .75
4 .75
Temperature setting (P&T valve)
°C
95
95
95
Pressure setting (P&T valve)
bar
6 .0
6 .0
6 .0
Expansion vessel size (volume)
litres
18
35
2 × 24
Expansion vessel initial charge pressure
bar
3
3
3
Height
A
mm
1,305
1,992
2,030
Diameter
B
mm
550
550
630
22 mm secondary return
C
mm
–
1,577
1,592
22 mm compression cold feed
D
mm
442
522
557
P&T valve
E
mm
1,053
1,720
1,784
22 mm solar return – bottom coil
F
mm
223
223
238
22 mm solar flow – bottom coil
G
mm
352
472
548
28 mm primary return – top coil
H
mm
467
742
641
28 mm primary flow – top coil
I
mm
1,072
1,562
1,791
Dual CT & OHT pocket – 1 top
J
mm
732
1,092
1,076
Dual CT & OHT pocket – 2 bottom
K
mm
419
539
651
Solar sensor pocket – 1 top
L
mm
882
1,367
1,382
Solar sensor pocket – 2 bottom
M
mm
203
262
334
3 kW immersion heater height
N
mm
457
702
640
Surface area of solar heater coil
m²
0 .68
0 .97
1 .27
Solar coil pressure loss
1
bar
0 .191
0 .241
0 .31
Primary heat exchanger surface area
m²
1 .36
2 .04
2 .91
Primary heat exchanger thermal rating
1
kW
24 .3
34 .2
47 .2
Primary heat exchanger pressure loss
1
bar
0 .048
0 .019
0 .027
Heat up time from 15 °C to 60 °C
2
min
33
48
49
Recovery time after 70 % draw-off
2
min
21
32
38
1
Measured at 0.25 l/s primary flow rate
2
Measured at 0.25 l/s primary flow rate and at 82 °C flow temperature
Table 1
L
H
K
N
D
F
J
A
I
G
M
C
E
40,00º
45,0
0º
35,00
º
25,00º
15,00º
Note
Not all models – see table 1.
Recovery times based
on Primary Coil/I.H. duty
(ie. assumes the boiler
output is adequate).
All connections are supplied
with compression fittings for
direct connection to copper
pipework .