For systems that support enhanced features version 2 or later (page 92)
Up to 10 distribution boxes can be connected to each branch from the control box.
Distribution box
DIP switch
Repeat switch
H
1 2 3 4 5 6 7 8
ON
OFF
(off)
(off)
I
1 2 3 4 5 6 7 8
ON
OFF
(off)
(off)
J
1 2 3 4 5 6 7 8
ON
OFF
(off)
(on)
*1 Each DIP switch setting can only be used one time per branch.
*2 In repeater mode, the repeat switch of one distribution box in the branch is set to the "on" position. All others are
set to the "off" position.
Only one distribution box per branch can be used in repeater mode.
Main monitors cannot be connected to a distribution box that is set to repeater mode.
*3 The terminate switch of the last distribution box in the branch is set to the "on" position. All others (except for a
distribution box that is operating in repeater mode) are set to the "off" position.
*4 The distribution box functioning in repeater mode can be located between the control box and a distribution box,
or between 2 distribution boxes.
*5
For systems that support enhanced features version 2 or later (page 92)
When connecting 8 or more distribution boxes, set the terminate switch of the 7th distribution box to the "off"
position.
41
4. Installation