Parameter
Description and available settings
Default
Door Key Open Code
Determines the door open code. If disabled, the door
cannot be opened using a code.
(4 digits, or #### to disable)
####
(DISABLE)
Door Key External In
Tells the system whether an access controller (door
opener, key switch, card reader, etc.) is connected to
the lobby station and used to unlock the door.
[0]: NO
[1]: YES
0
(NO)
Door Key In Signal
Determines whether the signal received from the
access controller is a closed signal (i.e., the signal is
normally open) or an open signal (i.e., the signal is
normally closed).
[0]: CLOSE
[1]: OPEN
0
(CLOSE)
Camera Connection
Tells the system whether a camera is connected or not.
[0]: NO
[1]: YES
0
(NO)
Camera Name
Determines the camera name.
[1]: CAMERA #
[2]: RECEPTION
[3]: GATE
[4]: CONTROL ROOM
[5]: RESTAURANT
[6]: HALL
[7]: POOL
[8]: SECURITY OFFICE
[9]: ENTRANCE
[10]: GYM
[11]: GUEST ROOM
[12]: KID’S ROOM
[13]: PARKING
[14]: TERRACE
[15]: LIFT LOBBY
1
(CAMERA #)
Camera Display Priority
Determines which camera image is displayed when
monitoring begins.
[0]: LOBBY
[1]: CAMERA
[2]: CAMERA ONLY
0
(LOBBY)
Camera Switching Image
Determines whether visitors (lobby station users) can
switch between the lobby station camera and the
external camera.
[0]: NO
[1]: YES
0
(NO)
Wide/Zoom
Determines whether camera images are displayed in
wide mode or in zoom mode when monitoring begins.
[0]: WIDE
[1]: ZOOM
0
(WIDE)
55
5. Programming
Содержание VL-V901
Страница 87: ...R Illustrations may vary slightly from the actual product 87 7 Other Information ...