2.
Open the knockout holes of the flush mount box, and then pass all necessary cables and wires (DC cable, wires
for control box, access controller, electric lock, etc.) through the knockout holes.
3.
Mount the box in the wall.
4.
Connect the wires and cables to the lobby station.
R
Strip the wires and cables as shown below.
R
See 4.5.1 Wiring schematics (Page 29) for wiring schematic diagrams.
A
D
B
E F G
C
H
I
9 mm
40 mm or more
12 mm
A
Cable release button for DC power
supply cable
B
DC cable from power supply unit
C
Hooks for securing the DC cable
D
Coaxial cable from external camera
E
Wires from control box or extension
box
F
Wires from access controller
G
Wires from electric lock
H
Wire release button
I
Connection terminal
R
To connect the DC cable from the power supply unit, press the cable release button while inserting the cable
into the connection terminals. (To disconnect the cable, press the button while pulling it out.) Use the hooks
to secure the cable.
R
To connect wires, press the wire release button with a pointed object such as a screwdriver while inserting the
wire into the connection terminal. (To disconnect a wire, press the button while pulling it out.)
R
Refer to 4.5.2 Wire type and maximum wire length (Page 36) for information on the type and length of wires
that can be used.