15
4.4.
Wall Mounting Construction
4.4.1.
Cautions for Wall Mounting Construction
Which method should be used to mount the elite Panaboard (unit) depends greatly on the structure of
the wall. The system to be mounted on the wall is heavy.
Before proceeding with installation, therefore, consult with the building manager, maintenance engineer
or designer to verify that the wall has a structure strong enough to support the weight of the system.
For safety, install the unit only after thoroughly understanding the type of walls, the appropriate types of
screws and the construction method.
Caution:
Do not attach the elite Panaboard to mortared walls.
Accidental electric leakage from the wall mounting plate bolts to metal laths or wire laths can cause heat,
smoke, or fire.
4.4.2.
Necessary Tools and Parts
(1) Tools
• Phillips Head Screwdriver
• Drill
• Measuring tape
• Level
• Dust pump
• Hammer
• Torque Driver (capable to specify torque
*
)
Note: *
The range in which the torque can be specified is limited.
Use the correct torque. (Recommended tightening torque: 5.2 N•m [53 kgf•cm])
(2) Parts
Note:
The specified pull-out strength is required per anchor.
M6 anchor bolts are used when installing the elite Panaboard on the wall.
(Specified pull-out strength: 784 N [80 kgf])
4.4.3.
Checkpoints to be Observed While Working
4.4.3.1.
Work-related Safety Precautions
Before mounting the electronic board, read through the following points, and take care to
avoid accidents.
(1) To ensure that the work is accomplished safely and properly, make it a basic rule to strictly observe all other applicable
aspects of safety control.
(2) If there is a chance that the unit has ended up being deformed or damaged by unexpected impact while it was being
transported and installed, do not install it without taking appropriate measures. Otherwise, it may fall off the wall.
4.4.3.2.
Concerning the Installation Surface
Avoid mounting the unit on a wall, which is not a principal structure component (a concrete wall which is at least
20 mm [4 3/4 in.] thick), with a plasterboard, plywood or other such construction since these walls are weak.
If mounting on such a wall is unavoidable, reinforce the wall adequately (by ensuring that its ultimate strength will
be at least as great as the specified pull-out strength of the anchors).
Classified Code
Part Name
Q'ty
Remarks
WS1
Anchor
8
WS2
M6 Bolt
8
Flat Washer
(max. diameter of 16 mm [0.63 in.])
4
Spring Washer
8
(11)
Flat Washer
(Diameter: 22 mm [0.87 in.])
4
included in this product
Содержание UB-T580
Страница 11: ...11 3 COMPONENT IDENTIFICATION 3 1 Main Unit ...
Страница 12: ...12 3 2 Stylus Pen ...
Страница 14: ...14 4 3 Included Accessories Confirm that the following items are included with the elite Panaboard ...
Страница 17: ...17 4 5 Unpacking the elite Panaboard from Its Packaging ...
Страница 23: ...23 13 Wipe the screen board surface Gently wipe the screen board surface with a soft moist cloth ...
Страница 28: ...28 5 SECTIONAL VIEW ...
Страница 48: ...48 12 CIRCUIT BOARDS Index 12 1 RELAY Board 12 2 LED Board ...
Страница 50: ...50 13 PARTS LOCATION AND MECHANICAL PARTS LIST ...
Страница 53: ...53 13 1 2 For UB T580W To be continued later ...
Страница 56: ...56 13 2 2 For UB T580W To be continued later ...
Страница 57: ...57 14 REPLACEMENT PARTS LIST ...