English
- 41 -
[Network] → [Advanced Settings] → [IP Configuration]
or [Network]
•• Command Port
[Network] → [Command Port].
2.
The display responds.
Response data
Data part
Space
Mode
Space
Random
Number
Part
Last
Terminal
Symbol
[NTCONTROL]
(ASCII
Character
string)
[ ]
0x20
[ 1]
0x31
[ ]
0x20
[zzzzzz]
(ASCII
Code
hex
number)
(CR)
0x0d
9 Bytes
1 Byte
1 Byte
1 Byte
8 Bytes
1 Byte
Mode = 1 (Fixed)
3.
Hash the following data with the MD5 algorithm,
and generate a 32-byte hash value.
[xxxxxx:yyyyy:zzzzzzzz]
xxxxxx :
[Network] – [Administrator Account] – [User Name]
yyyyy :
[Network] – [Administrator Account] – [Password]
● Set the user name and password you set for
[Administrator account].
zzzzzzzz :
8-byte random number obtained in step 2
Command transmission method
Transmit in the following command format
Transmitted data
Header
Data Part
Last
Terminal
Symbol
Hash value
(see
"Connection
method")
'0'
0x30
'0'
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
32 Bytes
1 Byte
1 Byte
Undefined
1 Byte
Received data
Header
Data Part
Last
Terminal
Symbol
'0'
0x30
'0'
0x30
Control
command
(ASCII
character
string)
(CR)
0x0d
1 Byte
1 Byte
Undefined
1 Byte
Error response
Error message
Last
Terminal
Symbol
"ERR1"
: Undefined control command
(CR)
0x0d
"ERR2"
: Out of parameter range
"ERR3"
: Busy status or reception
invalid period
"ERR4"
: Timeout or reception invalid
period
"ERR5"
: Wrong data length
"ERRA"
: Mismatching of password
4 Bytes
1 Byte
Note
•
With some of the commands, a part of character
string of the transmitted data may not be included
in the received data.
•
Consult your local Panasonic dealer for detail
instructions on command usage.
For more details, visit the following web site.
https://panasonic.net/cns/prodisplays