-41-
3. Move the cursor to ALARM IN 2, and then tilt the
joystick left and right to select the operation the
camera should perform when an external signal is
received by ALARM IN 2.
OFF
:
Ignore alarm input signals.
2POSI
:
Move to preset position 2.
SEQ
:
Start sequential movement.
PATROL2
:
Start PATROL 2.
PATROL2 (S) :
Start PATROL 2, and maintain the
stored picture quality settings
(page 35) even after completion.
AUTOTRACK2 :
Move to preset position number 2,
and then perform auto tracking.
4. Move the cursor to ALARM IN 3, and then tilt the
joystick left and right to select the operation the
camera should perform when an external signal is
received by ALARM IN 3.
OFF
:
Ignore alarm input signals.
3POSI
:
Move to preset position 3.
SORT
:
Start sort movement.
PATROL3
:
Start PATROL 3.
PATROL3 (S) :
Start PATROL 3, and maintain the
stored picture quality settings
(page 35) even after completion.
AUTOTRACK3 :
Move to preset position number 3,
and then perform auto tracking.
5. Move the cursor to ALARM IN 4, and then tilt the
joystick left and right to select the operation the
camera should perform when an external signal is
received by ALARM IN 4.
OFF
:
Ignore alarm input signals.
4POSI
:
Move to preset position 4.
BW
:
Black and white display while
signal is being input.
PATROL4
:
Start PATROL 4.
PATROL4 (S) :
Start PATROL 4, and maintain the
stored picture quality settings
(page 35) even after completion.
AUTOTRACK4 :
Move to preset position number 4,
and then perform auto tracking.
Notes:
• Use PATROL 1 (S) to 4 (S) if you want to switch
picture quality (for example to switch picture
quality from day to night) when an alarm input is
received. ALARM IN4 can be used combined
with BW.
To use the camera with this application, set the
picture quality you want to switch before
registering the patrol, then start the patrol
registration and then end the registration
immediately.
• If you want to change the picture quality settings
according to alarm input for PATROL 1 (S) to 4
(S), the settings are applied to the camera
settings and are kept even after the camera is
turned on again.
• PATROL1(S)-4(S) displays only the set number
of patrol routines (page 35).
6. Move the cursor to CNT-CLS 1, and then tilt the
joystick left and right to select the alarm output that
should be performed over ALARM OUT 1 when an
alarm is detected.
OFF
:
No alarm output
ALARM :
Output an alarm signal when an alarm is
detected by the motion detector (page 39)
or the preset alarm (page 40). After
selecting this setting, perform step 7 to
specify the alarm signal output time.
AUX1
:
Output a contact close signal when
AUX1 input is received from the system
controller.
7. If you selected ALARM in step 6, move the cursor to
TIME OUT and then tilt the joystick left and right to
select the alarm signal output time.
Tilting the joystick cycles through the output time
display in the sequence shown below. (unit: ms)
Note:
The shorter the duration, the more frequent
will be the detection output.
8. Move the cursor to CNT-CLS 2, and then tilt the
joystick left and right to select the alarm output that
should be performed from ALARM OUT 2 when an
alarm is detected.
OFF
:
No alarm output
BW
:
Output a contact close signal only while
the camera is in the black and white
mode.
AUX2
:
Output a contact close signal when
AUX2 input is received from the system
controller.
Note:
It is recommended to set the connected
external device to ignore the shorter alarm outputs
of 90 ms or less from the camera.
9. Move the cursor to COAX ALM OUT, and then tilt
the joystick left or right to toggle it on and off.
This setting turns alarm controls whether an alarm is
output when the camera moves to one of the preset
positions specified for ALARM IN 1 through 4 (1POSI,
2POSI, 3POSI, 4POSI) in steps 2 through 5, above.
ON
:
Output an alarm signal from the video
output connector at the point the camera
finishes moving to a preset position
(number 1 through 4) when there is alarm
input to ALARM IN (1 through 4).
OFF
:
No alarm signal output
Notes:
• The camera ignores alarm inputs during manual
operation.
• Turn off alarm outputs when the system controller
downloads or uploads the preset data.
100 MS
↔
200 MS
↔
1000 MS
↔
2000 MS
↔
4000 MS
WV-CW960_US 05.11.18 11:08 ページ41