10.2.1. SELECT THE BEST LOCATION
(Refer to “Select the best location”
section)
10.2.2. HOW TO FIX INSTALLATION
PLATE
The mounting wall is strong and solid enough to prevent it from
the vibration.
The centre of installation plate should be at more than 450 mm
at right and left of the wall.
The distance from installation plate edge to ceiling should more
than 67 mm.
From installation plate left edge to unit’s left side is 47 mm.
From installation plate right edge to unit’s right is 73 mm.
:
:
:
For left side piping, piping connection for liquid should be
about 14 mm from this line.
For left side piping, piping connection for gas should be
about 56 mm from this line.
For left side piping, piping connecting cable should be
about 785 mm from this line.
1. Mount the installation plate on the wall with 5 screws or
more.
(If mounting the unit on the concrete wall, consider using
anchor bolts.)
•
Always mount the installation plate horizontally by
aligning the marking-off line with the thread and using a
level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
•
Line according to the arrows marked on the lower left
and right side of the installation plate. The meeting point
of the extended line is the centre of the hole. Another
method is by putting measuring tape at position as
shown in the diagram above. The hole centre is
obtained by measuring the distance namely 150 mm
and 125 mm for left and right hole respectively.
•
Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
10.2.3. TO DRILL A HOLE IN THE WALL
AND INSTALL A SLEEVE OF
PIPING
1. Insert the piping sleeve to the hole.
2. Fix the bushing to the sleeve.
3. Cut the sleeve until it extrudes about 15 mm from the wall.
Caution
When the wall is hollow, please be sure to use the
sleeve for tube ass’y to prevent dangers caused by
mice biting the connecting cable.
4. Finish by sealing the sleeve with putty or caulking
compound at the final stage.
10.2.4. INDOOR UNIT INSTALLATION
1.
For the right rear piping
2.
For the right and right bottom piping
10.2. Indoor Unit
61
CS-XE9DKE CU-XE9DKE / CS-XE12DKE CU-XE12DKE
Содержание SUPER DELUXE CS-XE9DKE
Страница 10: ...4 Dimensions 10 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 11: ...11 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 12: ...5 Refrigeration Cycle Diagram 12 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 13: ...6 Block Diagram 13 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 14: ...7 Wiring Diagram 14 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 89: ...13 Technical Data 89 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 90: ...90 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 102: ...102 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 103: ...How to use electronic circuit diagram 103 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 104: ...18 1 Remote Control 104 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 105: ...18 2 Print Pattern Indoor Unit Printed Circuit Board Main 105 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...
Страница 107: ...18 5 Print Pattern Outdoor Unit Printed Circuit Board Main 107 CS XE9DKE CU XE9DKE CS XE12DKE CU XE12DKE...