36
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
2-5-4 Basic Wiring
; ; ; " * ;
The control output (OSSD 1 / 2) turns OFF if the light is blocked, while it automatically turns ON
if receives the light.
The auxiliary output is used to invalid the external device monitor function. At this time, set the
auxiliary output with “negative logic of the control output” (factory setting). The auxiliary output
cannot be connected to external devices.
<For PNP output>
Interlock function
Invalid (Auto-reset)
External device monitor function Invalid
Auxiliary output
Cannot be used
` ;" _ * # ? z z ]_z ;]z ;] Y
black, sky-blue / white, sky-blue / black, there is no lead wire.
K1
+
24V DC
±10%
-
Emitter
Receiver
Gray cable
Gray cable
with black line
K2
(Brown) +V
(Pale purple) Interlock setting input
(Yellow-green / Black) Auxiliary output
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Pink) Emission halt input / Reset input
(Shield) Output polarity setting wire
(Blue) 0V
(Yellow) Override input
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange) Synchroni
(Orange / Black) Synchronization -
(Yellow-green) External device monitor input
(Brown) +V
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-bule / White) Muting input A
(Sky-bule / Black) Muting input B
(Gray / Black) Interference prevention -
(Gray) Interference prev