51
© Panasonic Industriar Devices SUNX Co., Ltd. 2012 ME-SF4BV2-05
2-5-9 Wiring for Auto-reset (Interlock is Invalid)
(Wiring Example of the Control Category 4)
<For PNP output>
Interlock function
Invalid (Auto-reset)
External device monitor function Valid
Auxiliary output
Can be used
The device output is selected depending on the connecting state of the output polarity setting wire
(shield). Incorrect wiring may cause the lockout state.
* Symbols
Switch S1
@@#+@{ +"~^`"{^z|G`"
z#`<* {? ;]"; ^
`^ @GG];GG]*;
2) The circuit diagram shown above is for 12-core cable to be used. For 8-core cable, red, yellow, gray, gray /
black, sky-blue / white, sky-blue / black, there is no lead wire.
3) For resetting, refer to “
3-2 Interlock Function
.”
+
24V DC
±10%
-
K1
K2
Load
*S1
K1
K2
Receiver
Emitter
Gray cable
Gray cable
with black line
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Red) Muting lamp output
(Yellow) Override input
(Brown) +V
(Yellow-green) External device monitor input
(Brown) +V
(Shield) Output polarity setting wire
(Blue) 0V
(Sky-bule / White) Muting input A
(Sky-bule / Black) Muting input B
(Gray) Interference prev
(Gray / Black) Interference prevention -
(Pale purple) Interlock setting input
(Pink) Emission halt input / Reset input
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange) Synchroni
(Orange / Black) Synchronization -
(Blue) 0V
(Black) Control output 1 (OSSD 1)