3
1 Safety Precautions
1.1.
General Guidelines
1. IMPORTANT SAFETY NOTICE
There are special components used in this equipment which are important for safety. These parts are marked by
in the
Schematic Diagrams, Circuit Board Layout, Exploded Views and Replacement Parts List. It is essential that these critical parts
should be replaced with manufacturer’s specified parts to prevent X-RADIATION, shock fire, or other hazards. Do not modify
the original design without permission of manufacturer.
2. An Isolation Transformer should always be used during the servicing of AC Adaptor whose chassis is not isolated from the AC
power line. Use a transformer of adequate power rating as this protects the technician from accidents resulting in personal
injury from electrical shocks. It will also protect AC Adaptor from being damaged by accidental shorting that may occur during
servicing.
3. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
4. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
5. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
. When the exposed metal does not have a return path to the chas-
sis, the reading must be infinity.
1.1.2.
Leakage current hot check (See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect “A” to exposed metallic part on the set. And con-
nect “B” to a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 k
Ω
/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.25 V RMS.
A leakage current tester (Simpson Model 229 or equiva-
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
Figure 1
Содержание SDR-S50P
Страница 11: ...11 4 Specifications...
Страница 13: ...13...
Страница 14: ...14...
Страница 18: ...18 7 Service Fixture Tools 7 1 Service Tools and Equipment...
Страница 21: ...21 Fig D3 Fig D4...
Страница 24: ...24 Fig D13 Fig D14 Fig D15 Fig D16...
Страница 25: ...25 Fig D17 Fig D18 Fig D19 Fig D20...
Страница 26: ...26 Fig D21 Fig D22...
Страница 28: ...28 8 4 1 How to use of CCD positioning pin RFKZ0476...
Страница 30: ...30 9 2 2 Checking and repairing individual circuit boards How to use extension cables...
Страница 31: ...31 9 3 Location for Connectors of the Main P C B 9 3 1 Main P C B...
Страница 48: ...S 13...
Страница 49: ...S 14 S5 5 MONI FPC P C B FT901 1 2 S601 1 4 N M L K J I H G F E D SDR T55 T56 T51 T50 S50 MONI FPC P C B S 14...
Страница 50: ...S 15 2 4 SDR T55 T56 T51 T50 S50 MONI FPC P C B...
Страница 52: ...S 17 4 4 21 20 19 18 17 16 15 14 13 12 11 SDR T55 T56 T51 T50 S50 MONI FPC P C B...
Страница 55: ...S 20...
Страница 63: ...S7 2 LCD Section S 28 15 17 16 18 34 19 20 21 33 B17 B26 B27...