1.1.2. LEAKAGE CURRENT HOT CHECK (See
Figure 1
.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k , 10 watts resistor, in parallel with a 0.15 F
capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in
Figure 1
.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at
each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above
measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A
leakage current tester (Simpson Model 229 or equivalent) may be
used to make the hot checks, leakage current must not exceed 1/2
milliamp. In case a measurement is outside of the limits specified,
there is a possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the customer.
1.2. Before Repair and Adjustment
Disconnect AC power, discharge Power Supply Capacitors C5716, C5717, C5718 through a 10
, 10 W resistor to ground.
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may
destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
Current consumption at AC 230 V, 50 Hz in NO SIGNAL mode volume minimal should be ~ 600
mA (For E/ EG).
7
Содержание SA-HT990E
Страница 25: ...10 2 Main Components and P C B Locations 10 3 Disassembly of Top Cabinet Step 1 Remove 4 screws 25 ...
Страница 63: ...63 ...
Страница 64: ...23 2 Packaging 64 ...
Страница 69: ...Q2101 B1GFGCAA0001 TRANSISTOR M 69 ...
Страница 71: ...DIODES 71 ...
Страница 86: ...R6922 ERJ3GEYJ182V 1 8K 1 16W M 86 ...
Страница 100: ...C5722 ECJ1VB1H104K 0 1 50V M 100 ...
Страница 102: ...C6922 ECJ1VB1H473K 0 047 50V M 102 ...
Страница 109: ......
Страница 110: ...SURROUND ENHANCER unt of power ...
Страница 119: ......
Страница 179: ......