5. Extra pump cable shall be (2 x min 1.5 mm²), of type designation
60245 IEC 57 or heavier.
6. Boiler contact cable shall be (2 x min 0.5 mm²), of type
designation 60245 IEC 57 or heavier.
7. External control shall be connected to 1-pole switch with min
3.0 mm contact gap. Its cable must be (2 x min 0.5 mm
2
), double
insulation layer of PVC-sheathed or rubber-sheathed cable.
* note: - Switch used shall be CE compliance component.
-
Maximum operating current shall be less than 3A
rms
.
8. Tank sensor shall be resistance type, please refer to Graph 7.1 for
the characteristic and details of sensor. Its cable shall be (2 x min
0.3 mm
2
), double insulation layer (with insulation strength of min
30V) of PVC-sheathed or rubber-sheathed cable.
-30
-20 -10
0
10
20
30
16000
14000
12000
10000
8000
˚C
6000
4000
2000
0
Tank sensor characteristic
Resistance
Tank Sensor Resistance Vs Temperature
9. Room sensor zone 1 cable shall be (2 x min 0.3 mm²) double
insulation layer of PVC-sheathed or rubber-sheathed.
10. Outdoor air sensor cable shall be (2 x min 0.3 mm²) double
insulation layer of PVC-sheathed or rubber-sheathed.
11. Tank OLP cable must be (2 x min 0.5 mm
2
), double insulation
layer of PVC-sheathed or rubber-sheathed cable.
For S*C09*3E8
For S*C12/16*9E8
Bind optional
cables with
these bands
Power Supply 1
RCCB/ELCB
Power Supply 2
RCCB/ELCB
Holder (Clamper)
Indoor terminal
for connecting
cables
Bind optional
cables with
these bands
Main PCB
4
How to guide the optional cables and power supply cord
(view without internal wiring)
Optional cables:
•
External control
cable
•
Tank sensor cable
•
Room sensor
zone 1
•
Outdoor air sensor
cable
•
Tank OLP cable
•
Remote controller
cable
Optional cables:
•
3-way valve
cable
•
2-way valve cable
•
Room thermostat zone
1 cable
•
Booster heater cable
•
Extra pump cable
•
Boiler contact cable
•
Power Supply 1 cord
•
Power Supply 2 cord
•
Indoor Unit/Outdoor Unit Connecting cable
•
For connection to optional PCB
7
1. By connecting optional PCB, 2 Zone temperature control can
be achieved. Please connect mixing valves, water pumps and
thermistors in zone 1 and zone 2 to each terminals in optional
PCB.
Temperature of each zone can be controlled independently by
remote controller.
2. Pump zone 1 and zone 2 cable shall be (2 x min 1.5 mm²), of type
designation 60245 IEC 57 or heavier.
3. Solar pump cable shall be (2 x min 1.5 mm²), of type designation
60245 IEC 57 or heavier.
4. Pool pump cable shall be (2 x min 1.5 mm²), of type designation
60245 IEC 57 or heavier.
5. Room thermostat zone 1 and zone 2 cable shall be (4 x min
0.5 mm²), of type designation 60245 IEC 57 or heavier.
6. Mixing valve zone 1 and zone 2 cable shall be (3 x min 1.5 mm²),
of type designation 60245 IEC 57 or heavier.
7. Room sensor zone 1 and zone 2 cable shall be (2 x min 0.3 mm²),
double insulation layer (with insulation strength of minimum 30V)
of PVC-sheathed or rubber-sheathed cable.
8. Buffer tank sensor, pool water sensor and solar sensor cable
shall be (2 x min 0.3 mm²), double insulation layer (with insulation
strength of minimum 30V) of PVC-sheathed or rubber-sheathed
cable.
9. Water sensor zone 1 and zone 2 cable shall be (2 x min 0.3 mm²),
double insulation layer of PVC-sheathed or rubber-sheathed cable.
10. Demand signal cable shall be (2 x min 0.3 mm²), double insulation
layer of PVC-sheathed or rubber-sheathed cable.
11. SG signal cable shall be (3 x min 0.3 mm²), double insulation layer
of PVC-sheathed or rubber-sheathed cable.
12. Heat/Cool switch cable shall be (2 x min 0.3 mm²), double insulation
layer of PVC-sheathed or rubber-sheathed cable.
13. External compressor switch cable shall be (2 x min 0.3 mm²),
double insulation layer of PVC-sheathed or rubber-sheathed cable.
Bind optional
cables with
these bands
Optional
PCB
7
Bind all
optional cables
with these
bands
Bind optional
cables with
these bands
Bind all optional
cables with these
bands
Power Supply 1
RCCB/ELCB
Power Supply 2
RCCB/ELCB
Holder (Clamper)
Indoor
terminal for
connecting
cables
For S*C09*3E8
For S*C12/16*9E8
How to guide the optional cables and power supply cord
(view without internal wiring)
ACXF60-03130_EN ES IT.indb 16
ACXF60-03130_EN ES IT.indb 16
9/22/2016 4:21:32 PM
9/22/2016 4:21:32 PM
Содержание S*C09*3E8 Series
Страница 94: ...94 Memo ...
Страница 95: ...95 Memo ...
Страница 96: ...Printed in Malaysia ACXF60 03130 1 4 ...
Страница 190: ...94 Memo ...
Страница 191: ...95 Memo ...
Страница 192: ...Printed in Malaysia ACXF60 03130 2 4 ...