If the alarm display J01 appears, 

there is something wrong R32 

refrigerant leakage detection 

sensor or its wiring connection to 

the indoor unit.

 

Contact the service dealer 

immediately.

(It may not be detected when the 

refrigerant leaks.)
When the alarm display J02 

appears, it is the end of the 

life of the sensor board of R32 

refrigerant leakage detection 

sensor.

Contact the service dealer as 

soon as possible to replace the 

sensor board.

(If the sensor board is used as 

it is without being replaced, the 

sensor may be deteriorated and 

the refrigerant leakage may not 

be detected properly.)

This appliance is not intended for 

use by persons (including children) 

with reduced physical, sensory 

or mental capabilities, or lack of 

experience and knowledge, unless 

they have been given supervision 

or instruction concerning use of the 

appliance by a person responsible 

for their safety. Children should be 

supervised to ensure that they do 

not play with the appliance.
<for European market only>

This appliance can be used by 

children aged from 8 years and 

above and persons with reduced 

physical, sensory or mental 

capabilities or lack of experience and 

knowledge if they have been given 

supervision or instruction concerning 

use of the appliance in a safe 

way and understand the hazards 

involved. Children shall not play with 

the appliance. Cleaning and user 

maintenance shall not be made by 

children without supervision.
Do not turn the air conditioner on 

and off from the power mains switch. 

Use the ON/OFF operation button.
Do not stick anything into the 

air outlet of the outdoor unit. 

This is dangerous because the 

fan is rotating at high speed.
Do not touch the air inlet or 

the sharp aluminum fins of 

the outdoor unit. You may get 

injured.
Do not stick any object 

 

into the FAN CASE. You 

may be injured and the 

unit may be damaged.
Do not touch the fan because it 

automatically rotates when it detects 

a refrigerant leak. 

You may be injured.

WARNING

CAUTION

This appliance is intended to be used 

by expert or trained users in shops, 

in light industry and on farms, or for 

commercial use by lay persons.
Keep the fire alarm and the air outlet 

at least 1.5 m away from the unit.
Do not cool or heat the room too 

much if babies or invalids are 

present.

CAUTION

• The appliance shall be stored so as to prevent mechanical damage from occurring.

• The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers 

after a few minutes.

• The English text is the original instructions. Other languages are translation of the original instructions.

NOTICE

01_330422_EN.indb   5

2021/3/8   9:16:37

Содержание S-22MU2E5B

Страница 1: ...2E5B S 90MU2E5B S 36MU2E5B S 106MU2E5B S 45MU2E5B S 140MU2E5B S 56MU2E5B S 160MU2E5B S 60MU2E5B Connectable outdoor unit lineup OUTDOOR UNIT Refrigerant type R410A mini VRF Type LE1 LE2 2WAY VRF Type...

Страница 2: ...se as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product d...

Страница 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Страница 4: ...detect the refrigerant leakage when the refrigerant leaks and it may lead to cause the generation of toxic gas and fire Do not use the following items near the indoor unit and R32 refrigerant leakage...

Страница 5: ...ning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision D...

Страница 6: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Страница 7: ...te Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructions included with the Remote Controller W...

Страница 8: ...ration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric s...

Страница 9: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Страница 10: ...ntrol display shows at right NOTES z z Internal cleaning function is not possible to use any remote controller other than that of nanoe X function z z When connected to the remote controller which is...

Страница 11: ...nt leakage detection sensor is connected and the refrigerant leaks P08 alarm and inspection mark will be displayed on the remote controller and the fan will automatically operate Please ventilate the...

Страница 12: ...does not stop even when you press ON OFF operation button on remote controller R32 refrigerant leakage detection sensor connected to the indoor unit has detected refrigerant leakage In such a case do...

Страница 13: ...8 ME2 3 phase U 8ME2E8 U 10ME2E8 MF3 3 phase U 8MF3E8 U 10MF3E8 Outdoor unit type 12 HP 14 HP 16 HP 18 HP 20 HP ME2 3 phase U 12ME2E8 U 14ME2E8 U 16ME2E8 U 18ME2E8 U 20ME2E8 MF3 3 phase U 12MF3E8 U 14...

Страница 14: ...ns H W D mm 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 Net weight kg 24 24 24 24 24 25 Model Name S 73MU2E5B S 90MU2E5B S 106MU2E5B S 140MU2E5B S 160MU2E5B Pow...

Страница 15: ...6 C 30 C DB In the case of nanoe X OFF Values include the dimensions and weight of an optional ceiling panel Fan speed display on the remote controller High CZ RTC4 CZ RTC5B CZ RTC6 Medium CZ RTC4 CZ...

Страница 16: ...8 U 6LZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 12 1 14 0 15 5 Heating capacity kW 12 5 16 0 16 5 Sound pressure level Cooling Heating dB A 52 54 53 56 54 56 Sound power level Cooli...

Страница 17: ...0 1 500 980 370 Net weight kg 132 133 Operation condition temperature range Cooling mode 10 C 52 C DB Heating mode 20 C 18 C WB Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor...

Страница 18: ...e the Panasonic website for further information on collection centers etc or call the customer care toll free number http www panasonic com in corporate sustainability panasonic india i recycle progra...

Отзывы: