17
Model Name
U-8LZ2E8
U-10LZ2E8
Power source
380 - 400 - 415 V 3N
~
50 Hz
Cooling capacity
kW
22.4
28.0
BTU/h
76,500
95,600
Heating capacity
kW
25.0
28.0
BTU/h
85,300
95,600
Sound pressure level
dB(A)
60
63
Sound power level
dB(A)
81
84
Unit dimensions
(H×W×D)
mm
1,500×980×370 1,500×980×370
Net weight
kg
132
133
Operation condition temperature range
• Cooling mode : -10°C~52°C DB
• Heating mode : -20°C~18°C WB
Rated conditions
Cooling : Indoor intake air temp. 27°C DB / 19°C WB. Outdoor intake air temp. 35°C DB.
Heating : Indoor intake air temp. 20°C DB. Outdoor intake air temp. 7°C DB / 6°C WB.
mini VRF (Type LE1, LE2)
2WAY VRF (Type ME2)
3WAY VRF (Type MF3)
NOTE
Refer to the Operating Instructions attached to the outdoor unit.