background image

2

z

z

Safety Precautions

 ...........................................................

2

z

z

Precautions for Use

 .........................................................

6

z

z

Names of Parts

 .................................................................

7

z

z

Maintenance

 .....................................................................

8

• 

Operation Mechanism

 ...................................................

8

z

z

nanoe™ X Function

 .........................................................

9

z

z

Troubleshooting

 .............................................................

11

• 

Before Requesting Services

 .......................................

12

z

z

Specifications

 .................................................................

14

• 

Indoor unit

 ....................................................................

14

• 

Outdoor unit

 .................................................................

16

Contents

Thank you for purchasing this Panasonic product.

This product is a commercial air conditioner indoor unit.

Installation Instructions attached.

Product Information

If you have problems or questions concerning your Air 

Conditioner, you will need the following information. Model and 

serial numbers are on the nameplate.

Model No. 

Serial No. 

Date of purchase

Dealer’s address

Phone number

Safety Precautions

The following symbols used in this manual, alert you to 

potentially dangerous conditions to users, service personnel or 

the appliance:

WARNING

This symbol refers to a hazard or 

unsafe practice which can result in 

severe personal injury or death.

CAUTION

This symbol refers to a hazard or 

unsafe practice which can result 

in personal injury or product or 

property damage.

Prohibited matters

Matters to be 

 

observed

• Read these Operating Instructions carefully before using this 

air conditioner. If you still have any difficulties or problems, 

consult your dealer for help.

• This air conditioner is designed to give you comfortable 

room conditions. Use this only for its intended purpose as 

described in these Operating Instructions.

Confirm to authorized dealer 

or specialist on usage of 

specified refrigerant type. Using 

of refrigerant other than the 

specified type may cause product 

damage, burst and injury etc.
This air conditioner has no 

ventilator for intaking fresh air 

from outdoors. You must open 

doors or windows frequently 

when you use gas or oil heating 

appliances in the same room, 

which consume a lot of oxygen 

from the air. 

Otherwise there is a risk of 

suffocation in an extreme case.
Never use or store gasoline or 

other flammable vapor or liquid 

near the air conditioner — it is 

very dangerous.
Do not use this appliance in a 

potentially explosive atmosphere.
Never touch the unit with wet 

hands.
Do not insert your fingers or 

 

other objects into the air 

conditioner indoor or 

outdoor unit, rotating parts may 

cause injury.

WARNING

WARNING

This symbol shows that this equipment 
uses a flammable refrigerant. If the 
refrigerant is leaked, together with 
an external ignition source, there is a 
possibility of ignition.

CAUTION

This symbol shows type of flammable 
refrigerant contained in the system.

CAUTION

This symbol shows that a service 
personnel should be handling this 
equipment with reference to the 
Technical Manual.

CAUTION

This symbol shows that there is 
information included in the Operating 
Instructions and/or Installation Instructions.

Important Information Regarding The  

Refrigerant Used

NOTE

Refer to the Installation Instructions attached to the 

outdoor unit.

01_330422_EN.indb   2

2021/3/8   9:16:36

Содержание S-22MU2E5B

Страница 1: ...2E5B S 90MU2E5B S 36MU2E5B S 106MU2E5B S 45MU2E5B S 140MU2E5B S 56MU2E5B S 160MU2E5B S 60MU2E5B Connectable outdoor unit lineup OUTDOOR UNIT Refrigerant type R410A mini VRF Type LE1 LE2 2WAY VRF Type...

Страница 2: ...se as described in these Operating Instructions Confirm to authorized dealer or specialist on usage of specified refrigerant type Using of refrigerant other than the specified type may cause product d...

Страница 3: ...oles must be incorporated in the fixed wiring in accordance with the wiring rules To prevent possible hazards from insulation failure the unit must be grounded WARNING Do not use modified cord joint c...

Страница 4: ...detect the refrigerant leakage when the refrigerant leaks and it may lead to cause the generation of toxic gas and fire Do not use the following items near the indoor unit and R32 refrigerant leakage...

Страница 5: ...ning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision D...

Страница 6: ...recovery and recycling of old products and used batteries please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC and 2006 66 EC By...

Страница 7: ...te Controller The flap display on the remote controller differs from the actual flap angle A Model No CZ RTC4 For all indoor units Read the Operating Instructions included with the Remote Controller W...

Страница 8: ...ration automatically Operation settings prior to power failure will be used WARNING z z For safety be sure to turn the air conditioner off and disconnect the power before cleaning Otherwise electric s...

Страница 9: ...opagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptab...

Страница 10: ...ntrol display shows at right NOTES z z Internal cleaning function is not possible to use any remote controller other than that of nanoe X function z z When connected to the remote controller which is...

Страница 11: ...nt leakage detection sensor is connected and the refrigerant leaks P08 alarm and inspection mark will be displayed on the remote controller and the fan will automatically operate Please ventilate the...

Страница 12: ...does not stop even when you press ON OFF operation button on remote controller R32 refrigerant leakage detection sensor connected to the indoor unit has detected refrigerant leakage In such a case do...

Страница 13: ...8 ME2 3 phase U 8ME2E8 U 10ME2E8 MF3 3 phase U 8MF3E8 U 10MF3E8 Outdoor unit type 12 HP 14 HP 16 HP 18 HP 20 HP ME2 3 phase U 12ME2E8 U 14ME2E8 U 16ME2E8 U 18ME2E8 U 20ME2E8 MF3 3 phase U 12MF3E8 U 14...

Страница 14: ...ns H W D mm 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 289 5 950 950 Net weight kg 24 24 24 24 24 25 Model Name S 73MU2E5B S 90MU2E5B S 106MU2E5B S 140MU2E5B S 160MU2E5B Pow...

Страница 15: ...6 C 30 C DB In the case of nanoe X OFF Values include the dimensions and weight of an optional ceiling panel Fan speed display on the remote controller High CZ RTC4 CZ RTC5B CZ RTC6 Medium CZ RTC4 CZ...

Страница 16: ...8 U 6LZ2E8 Power source 380 400 415 V 3N 50 Hz Cooling capacity kW 12 1 14 0 15 5 Heating capacity kW 12 5 16 0 16 5 Sound pressure level Cooling Heating dB A 52 54 53 56 54 56 Sound power level Cooli...

Страница 17: ...0 1 500 980 370 Net weight kg 132 133 Operation condition temperature range Cooling mode 10 C 52 C DB Heating mode 20 C 18 C WB Rated conditions Cooling Indoor intake air temp 27 C DB 19 C WB Outdoor...

Страница 18: ...e the Panasonic website for further information on collection centers etc or call the customer care toll free number http www panasonic com in corporate sustainability panasonic india i recycle progra...

Отзывы: