SPECIAL REMARKS

Heating Performance

Since this air conditioner utilizes outside air for heating, its heating performance 
deteriorates as outside temperature decreases. (Due to heat pump system)

It will take some time until the room becomes warmer after heating operation started. (Due 
to hot air circulation system in order to heat a whole room)

Defrosting

This appliance may start defrosting operation to melt frost form in the outdoor unit during 
long hour heating operation mode.
The indoor unit fan will stop for about 5 to 10 minutes at this time.

Heating Standby

The remote controller shows “

” (Heating standby) on the display in the following mode and 

the indoor unit fan may be controlled.

When operation started (Indoor unit fan stops for maximum 6 minutes.)

When Thermostat activated

When defrosting (Indoor unit fan stops.)

When Heating Operation

Started (Only 3WAY VRF)

When changed to heating mode from stopped or cooling operation mode, the unit does not 
work for about 3 minutes for the sake of self-protection.
It may take about 5 to 10 minutes until the hot air is delivered after starting the heating 
operation.

Oil Recovery

The indoor unit fan may stop or run at a slow speed in order to recover the oil in the system 
every 1 to 3 hours during cooling or heating operation.
The unit will automatically resume the original operation after about 5 to 10 minutes.

Remote Control Sensor

The temperature sensor in the indoor unit normally senses the room temperature and can also 
sense the ambient temperature of the remote controller.
For the details, consult the shop you purchased.

Should the power failure

occurs while the

unit is running

When the unit automatically resumes operation after temporary power failure, it uses the same 
settings before the power was cut off.

F570001_EN.fm  Page 7  Tuesday, June 23, 2015  9:25 AM

Содержание S-12MT2U6

Страница 1: ...1U6 Indoor Unit Type Type Outdoor Units Nominal Capacity ME2 2WAY VRF System MF2 3WAY VRF System LE1 Mini VRF System Outdoor Unit Type Type 36 72 U 72ME2U9 U 72MF2U9 96 U 96ME2U9 U 96MF2U9 120 U 120ME...

Страница 2: ...ICATIONS 11 PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate of the unit Mode...

Страница 3: ...ith a ground or earth wire or through the supply wiring Wiring must be done by a qualified electrician To warm up the system the power mains must be turned on at least five 5 hours before operation Le...

Страница 4: ...ies or invalids are present Do not sit or step on the unit You may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The compressor may oc...

Страница 5: ...ling Refer to the Operating Instructions attached to the optional Timer Remote Controller Refer to the Operating Instructions attached to the optional High spec Wired Remote Controller Ceiling panel o...

Страница 6: ...your hands B Horizontal directions manual The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right If multiple indoor units are connected to a remot...

Страница 7: ...hen defrosting Indoor unit fan stops When Heating Operation Started Only 3WAY VRF When changed to heating mode from stopped or cooling operation mode the unit does not work for about 3 minutes for the...

Страница 8: ...de be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe plastic parts using very hot water 2 Some metal edges and the fins a...

Страница 9: ...gh operation stops Fan rotating makes operation smoothly Fan may sometimes rotate because of drying heat exchanger due to settings Wind direction changes while operating Wind direction setting cannot...

Страница 10: ...openings closed Should the power fail while the unit is running If the power supply for this unit is temporarily cut off the unit will automatically resume operation once power is restored using the s...

Страница 11: ...290 13 29 32 353 W inch mm 37 13 32 950 37 13 32 950 D inch mm 37 13 32 950 37 13 32 950 Net Weight unit panel lbs kg 53 9 24 4 60 9 27 4 Model Name S 12MT2U6 S 18MT2U6 S 24MT2U6 Power Source 208 230...

Страница 12: ...F570001 BE0515 10615 Panasonic Corporation 2015 Printed in China...

Отзывы: