background image

11

SPECIFICATIONS

„

4-Way Cassette 36" x 36" (Type U2)

* Values include the dimension and weight of an optional ceiling panel.

„

Ceiling (Type T2)

Model Name

S-24MU2U6

S-36MU2U6

Power Source

208 / 230 V, 60 Hz, 1PH

Cooling Capacity

BTU/h

25,000

36,000

kW

7.3

10.6

Heating Capacity

BTU/h

27,000

39,000

kW

7.9

11.4

Sound Pressure Level (High/Medium/Low)

dB(A)

37/32/29

44/38/34

Unit Dimensions*

H : inch (mm)

11-7/16 (290)

13-29/32 (353)

W : inch (mm)

37-13/32 (950)

37-13/32 (950)

D : inch (mm)

37-13/32 (950)

37-13/32 (950)

Net Weight: unit + panel

lbs. (

kg

)

53+9 (24+4)

60+9 (27+4)

Model Name

S-12MT2U6

S-18MT2U6

S-24MT2U6

Power Source

208 / 230 V, 60 Hz, 1PH

Cooling Capacity

BTU/h

12,000

19,000

25,000

kW

3.5

5.6

7.3

Heating Capacity

BTU/h

14,000

21,000

27,000

kW

4.1

6.2

7.9

Sound Pressure Level (High/Medium/Low)

dB(A)

36/32/30

37/33/30

39/35/33

Unit Dimensions

H : inch (mm)

9-1/4 (235)

9-1/4 (235)

9-1/4 (235)

W : inch (mm)

37-51/64 (960)

37-51/64 (960)

50-13/64 (1,275)

D : inch (mm)

27-11/64 (690)

27-11/64 (690)

27-11/64 (690)

Net Weight

lbs. (

kg

)

60 (27)

60 (27)

73 (33)

F570001_EN.fm  Page 11  Tuesday, June 23, 2015  9:25 AM

Содержание S-12MT2U6

Страница 1: ...1U6 Indoor Unit Type Type Outdoor Units Nominal Capacity ME2 2WAY VRF System MF2 3WAY VRF System LE1 Mini VRF System Outdoor Unit Type Type 36 72 U 72ME2U9 U 72MF2U9 96 U 96ME2U9 U 96MF2U9 120 U 120ME...

Страница 2: ...ICATIONS 11 PRODUCT INFORMATION If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate of the unit Mode...

Страница 3: ...ith a ground or earth wire or through the supply wiring Wiring must be done by a qualified electrician To warm up the system the power mains must be turned on at least five 5 hours before operation Le...

Страница 4: ...ies or invalids are present Do not sit or step on the unit You may fall down accidentally Do not stick any object into the FAN CASE You may be injured and the unit may be damaged The compressor may oc...

Страница 5: ...ling Refer to the Operating Instructions attached to the optional Timer Remote Controller Refer to the Operating Instructions attached to the optional High spec Wired Remote Controller Ceiling panel o...

Страница 6: ...your hands B Horizontal directions manual The horizontal airflow direction can be adjusted manually by moving the vertical vanes to the left or right If multiple indoor units are connected to a remot...

Страница 7: ...hen defrosting Indoor unit fan stops When Heating Operation Started Only 3WAY VRF When changed to heating mode from stopped or cooling operation mode the unit does not work for about 3 minutes for the...

Страница 8: ...de be careful not to force the vanes out of place 1 Never use solvents or harsh chemicals when cleaning the indoor unit Do not wipe plastic parts using very hot water 2 Some metal edges and the fins a...

Страница 9: ...gh operation stops Fan rotating makes operation smoothly Fan may sometimes rotate because of drying heat exchanger due to settings Wind direction changes while operating Wind direction setting cannot...

Страница 10: ...openings closed Should the power fail while the unit is running If the power supply for this unit is temporarily cut off the unit will automatically resume operation once power is restored using the s...

Страница 11: ...290 13 29 32 353 W inch mm 37 13 32 950 37 13 32 950 D inch mm 37 13 32 950 37 13 32 950 Net Weight unit panel lbs kg 53 9 24 4 60 9 27 4 Model Name S 12MT2U6 S 18MT2U6 S 24MT2U6 Power Source 208 230...

Страница 12: ...F570001 BE0515 10615 Panasonic Corporation 2015 Printed in China...

Отзывы: